52
O p e r a t i n g / s e r v i c i n g E L 4 0
(EL = electronic version)
What to do when warnings or error messages
are displayed?
Note the letter/number combination shown on the display.
Pass the number combination and, if possible, the associated
cause explained in the following list, as soon as you contact
your sanitary dealer. The dealer can then react quickly to the
malfunction.
Warnings/Error Messages
In addition to normal information, e.g. water temperature, the
K4 control also displays warnings and error messages.
Warnings and error messages can be distinguished as follows:
Warnings
(e. g.
A01
) signal unusual operating conditions.
Although the respective operating status can somewhat restrict
shower performance,
you can still take showers.
Error messages
(e. g.
F01
) also signal unusual operating
conditions. Here however, shower operation remains complete-
ly blocked until the error has been cleared. This prevents any
hazards to the user.
List of possible warnings/error messages on the K4 display:
Warning
Possible cause
A01
Thermostat motor current too low
Cable break, plug connection
A03
Thermostat motor current too high
Control unit sluggish
A05
Resistance of thermostat potentiometer too low
Cable break, plug connection motor
A07
Resistance of thermostat potentiometer too high
Cable break, plug connection motor
A11
Improbable values from temperature sensor
Cable break, plug connection, temperature sensor defective
A12
Teaching aborted (error during motor adjustment)
Not enough water, pressure differences
temperatures
Error messages
Posible cause
F01
Keyboard 1 not responding
Keyboard defective
F03
Extension module not responding
Extension module defective
F09
Controller error
Basic unit defective
F14
Motor current, motor temperature too high,
nominal temperature >42° C
Control unit sluggish