MilkyWay
MilkyWay Handbook • Version 3 - 20140616 © Handicare AB
For use in combination with:
Rail 64
Rail 120
Rail 160
50400191
50400318
For more information about MilkyWay; available parts, article numbers and
technical data, please consult the “MilkyWay Technical information” document.
50400193
50400235
9: Wall fixtures - brackets and vertical supports / 61
9.6.1: Vertical support adjustable, angled installation
Application: Basic rail systems and rail systems with full room coverage. For mounting in angle when the rail can not
be perpendicular. The shown mounting can be used on high quality plasterboard walls provided that the fitter uses
the correct anchors.
Minimum requirements are:
• Rigid connection between wall and ceiling.
35 Nm
50 Nm
20 mm
A
51
2230-2300 mm min-max
A = Rail max. 60 mm shorter than the wall measure, min. 40 mm.
B = Bracket lowers the system by 6 mm.
C = Vertical support adjustable kit (50400191) adds 135 mm to the height of the system
D = Rail mounted on top of the profile adds 10 mm to the top measure
D
Vertical support adjustable
– angle
Application: for fixing to the
rail in angle the standard
clasp must be replaced by
clasp nut 8 mm, 50400194,
according to figure. Secure
the rail.
Vertical support adjustable
– angle
Application: for fixing to the
rail on top fo the supprt and
in angle the standard clasp
must be replaced by clamp
bracket, 50400193,
according to figure.
Secure the rail.
35 Nm
50 Nm
20 mm
C = Accessories
A For detailed information about maximum free span
and overhang for different rail profiles installed on
different types of ceilings and walls using different
types of fixtures, please consult the ”MilkyWay
Technical information” document; Span details.
B
D
A