MilkyWay
MilkyWay Handbook • Version 3 - 20140616 © Handicare AB
4: Rail systems with full room coverage - (x-y)/traverse systems / 35
Transition gates between two systems with full room coverage consist of two individual transition gates mounted as
shown on a short single rail. The fixed rails can normally not be wall mounted. Ceiling bracket standard 50400319 or
wall brackets types 50400120 or 50400119 can be used. The transition gate is fixed to the ceiling using adjustable
ceiling pendant, for example types 50400164 or 50400165.
Tongue piece engaged
Adjustable pendants
Locking gate
M
in
. 4
00 m
m
4.4.3: Transition gates between two systems with full room coverage