Turbine Alignment Hardware 

 

The L-705 and L-706 Bore Alignment Lasers are perfectly designed to 

perform alignment of gas and steam turbine bores. The system uses a 

laser, reference target, measuring target, micrometer sweep device, and 

fixtures to hold the laser and targets. Since the laser beam is concentric 

to the OD of the L-705/706 housing to within .0005 in. (0.013 mm), it 

can serve as one reference target. This saves a lot of time during setup. 

 

On most turbine alignments, the rotor bearing bores are used as the 

references. This means that fixtures that hold the laser and reference 

target must be placed precisely in these bores to the set points determined 

by the manufacturer of the turbine.  

 

The fixtures are hung in the bores using angle iron and special magnetic 

bases. Depending upon the size of the bore, either the large (A-501) or 

the small sweep unit (A-501A) is used to position the fixture so that the 

center is exactly on the reference points provided. The sweep unit is 

essentially an inside micrometer that allows the fixture to be placed to 

any points desired (for example, .000 in. left, .009 in. right and -.010 in. 

bottom). 

 

Once both fixtures are swept in, the laser (L-705 for distances up to 50 ft. 

(15 m) and the L-706 for distances from 50 to 110 ft. or 15 m to 33 m) is 

placed in one reference fixture and a target (T-218T) is placed in the 

opposite reference fixture. The L-705 laser is manufactured so that the 

laser beam is concentric (centered to) to the housing's OD to within 

.0005 in. (0.013 mm). With the fixture "swept in," the laser is inserted 

into the fixture and is thus centered to the reference points.  

 

All that is needed now is to adjust the angle of the laser beam, using the two micrometers on the back of 

the L-705. These micrometers are adjusted until the reference target reads zero, both vertically and 

horizontally. The laser is now set up and ready for measurements. 

 

For measuring an individual component, such as a diaphragm, there are two target choices. The first is 

the T-218T Turbine Target. The T-218T works much the same as the reference targets. The target fixture 

(A-502A) is swept into the center of the bore using the A-501(A) sweep unit, then the target is placed in 

the fixture and the reading is taken. A positive vertical reading means the diaphragm is higher than the 

reference bores. A positive horizontal reading means the diaphragm is to the right of the reference bores. 

Since the data is live, the diaphragm can be adjusted until the reading is zero (or to an offset determined 

by the engineers). 

 

The second measuring target that can be used is the A-1511 Wand Bore Target. Instead of using a fixture 

to "hang" a target in the center of the bore, the A-1511 uses fixed-length legs that are approximately 

equal to the radius of the bore. Two legs are used, each 90 degrees from the other. One leg has a 

measuring tip on it and the other is used for support. The A-1511 has replaceable legs and can be used on 

bores with a radius of 10 to 96 in. (254 mm to 2.44 m). 

 

Recommended System 

Configuration 

L-705 Bore Laser 

R-1307-2.4ZB Target Readout 

T-218T 2-Axis Turbine Target 

A-501A Turbine Small Bore 

Sweep Unit 

A-502A Turbine Reference 

Target Bracket 

A-502L Laser Support Bracket 

T-231A 25 ft. (7.62 m) Target 

Extension Cable 

A-510 Self-Centering Small Bore 

Target Adapter for 2 – 5 in. 

Bores 

A-814 Shipping Case 

 

Optional Accessories

 

L-706 Long Distance Bore Laser  

A-1511 Wand Bore Target 

A-501A Turbine Bore Sweep 

Unit  

A-1519-2.4ZB Single-Axis 

2.4GHz Wireless Scan Target 

R-1308 Single-Axis Readout 

A-1356-2.4ZB Ruggedized 

Nomad PDA with Read15 

Software 

 

Содержание L-705

Страница 1: ......

Страница 2: ...icles of equipment manufactured by other companies and limited by a warranty extending for less than one year In such an event the more limited warranty applies to said instrument or article of equipm...

Страница 3: ...ac Man Magnets 7 Using the T 218T 2 Axis Turbine Target 14 Measuring Bores Using the A 1511 Wand Bore Target R 1308 Readout 16 Calculating the Bore Misalignment 18 Measuring Bores Using the A 1511 Wan...

Страница 4: ...he two micrometers on the back of the L 705 These micrometers are adjusted until the reference target reads zero both vertically and horizontally The laser is now set up and ready for measurements For...

Страница 5: ...ly following the NORMIN procedure described in Appendix A accuracies of 0002 in 0 005 mm in 10 ft 3 m can also be achieved The L 705 has a range of 50 ft 15 m and under good environmental conditions i...

Страница 6: ...05 Laser The L 705 Laser beam is factory adjusted to be concentric to the mounting diameters 2 25 in or 57 15 mm and 75 in or 19 05 mm within 0005 in 0 0127 mm With the adjusting micrometers set at th...

Страница 7: ...on the micrometer control at the apex of the V and H axis arrows Insert the plug gently until it snaps into place Replacing the Batteries The battery pack uses two 9 volt batteries The batteries are h...

Страница 8: ...reference bores Since the data is live the diaphragm can be adjusted until the reading is zero or to an offset determined by the engineers Figure 4 T 218 Target A 1511 Wand Bore Fixture The A 1511 Wa...

Страница 9: ...1308 Single Axis Readout The R 1308 Single Axis Readout is a small lightweight readout that attaches to the base post of Hamar Laser s A 1519 2 4ZB Wireless Targets and connects directly to the targe...

Страница 10: ...ck out machines for stationary procedures If a machine is running set up barriers and or warning signs and route all cables away from moving parts Clean and check all equipment fixtures and mounting s...

Страница 11: ...to absorb any angularity that may occur when tightening the set screws against the angle iron Tighten the set screw in the rotating slot magnetic mount against the angle iron Place one of each of the...

Страница 12: ...iron and onto the second length of angle iron Use a measuring tape to center the A 502L with the bore from side to side The magnetic mounts are designed so that the A 502L will be very near to the cen...

Страница 13: ...d the reference bore Place the tip onto the bore surface so it will hold the rod from falling out The Bore Sweep Unit has a linear bearing slide so the rod cannot rotate when it is inserted into the u...

Страница 14: ...the A 502 in the bore according to the desired offsets determined by the shaft centerline Note The adjustment knobs are only push adjustments One knob must be loosened and the opposite knob tightened...

Страница 15: ...sired set point if necessary If any adjustment is made the Digital Dial Indicator must be e re zeroed at the original set point Move the Bore Sweep Rod tip to the bottom of the bore Position the A 502...

Страница 16: ...t the angle iron in the straight slot magnetic mount Tighten the set screw in the rotating slot magnetic mount Using a measuring tape position the A 502 onto the angle iron horizontally near the cente...

Страница 17: ...zontally by turning the vertical and horizontal adjustments on the front of the L 705 laser If the laser beam is not going into the front opening of the T 218T 2 Axis Turbine Target it may be necessar...

Страница 18: ...15 Half Bore Alignment Setup...

Страница 19: ...he R 1307 Readout for dual axis mode see Appendix B beginning on Page 24 Using a measuring tape measure the diameter of the bore Select the appropriate legs and or extensions that can be adjusted to t...

Страница 20: ...ou get the highest number reading on the readout When you have the highest number reading on the readout press the ABS REL Button on the front of the R 1308 Readout to zero the reading Rotate the targ...

Страница 21: ...eep the target in and out until you get the highest number reading on the readout Record that number on the sheet of paper Calculating the Bore Misalignment Left side of bore target reading 000 Right...

Страница 22: ...e the measuring tip on the side of the bore so it is resting on the support leg Adjust the support leg until the horizontal reading on the R 1307 readout is less than 030 in 0 77mm Adjust the measurin...

Страница 23: ...less than 030 in 0 77mm Slowly sweep the target in and out until the highest number displays on the R 1307 Readout Record that number on a sheet of paper Note Be sure to note whether the number is po...

Страница 24: ...sitive or negative Repeat this procedure in each of the components to be measured Calculating the Bore Misalignment Left side of bore target reading 000 Right side of bore target reading 026 The bore...

Страница 25: ...re alignments the True Bore Center the Target Center and the Laser Reference Centerline If mounting fixtures were perfect the Target Center would be located at the True Bore Center and if perfectly al...

Страница 26: ...n the readout are also rotated Therefore although the Target Center appears to be to the right of and lower than the Laser Beam Center in Figure 10 the vertical readings are positive and the horizonta...

Страница 27: ...24 Appendix B Configuring the R 1307 2 4ZB Readout Model R 1307 Readouts Control Panel...

Страница 28: ...types TGT 0 for HLI use only Do not use TGT nn P 10 10 10x10 mm sensor pulsed beam mode TGT nn F 10 10 10x10 mm sensor fixed beam mode TGT nn P 4 4 4x4 mm sensor pulsed beam mode TGT nn F 4 4 4x4 mm s...

Страница 29: ...stem ID dial on the side of the target is set to 1 7 Press the Menu button until displays in the Vertical Display window Use the up or down arrow keys until displays in the Horizontal Display window A...

Страница 30: ...the type intended for nail polish removal NOTE When cleaning precision optics even with the best quality optical cleaning tissue use gentle pressure to avoid scratching the surface or damaging the opt...

Отзывы: