18
Press the
Display Mode
button on the readout to
display the horizontal bars. Adjust the support leg
until fewer than three bars are showing. Press the
Display Mode
button again to display the vertical
reading. Slowly sweep the target in and out until
you get the highest number reading on the
readout. Record that number on the sheet of
paper.
Calculating the Bore Misalignment
Left side of bore target reading = .000
Right side of bore target reading = +.026
The bore is misaligned by half of the reading (.013 – measured from the right side, looking into the
target)
Bottom of bore target reading = -.045.
The bore is misaligned by -.045 minus .013 or -.032 (Low)