5

 

 

T-218T 2-Axis Turbine Target 

 

The T-218T turbine target works much the same as reference 

targets. The target fixture (A-502A) is swept into the center of 

the bore using the A-501(A) sweep unit, then the target is placed 

in the fixture and the reading is taken. A positive vertical reading 

means the diaphragm is higher than the reference bores. A 

positive horizontal reading means the diaphragm is to the right of 

the reference bores. Since the data is live, the diaphragm can be 

adjusted until the reading is zero (or to an offset determined by 

the engineers). 

 

 

 

 

 

 

 

Figure 4 – 

T-218 Target 

 

 

A-1511 Wand Bore Fixture 

 

The A-1511 Wand Bore Fixture 

speeds data taking for steam turbine 

bores with diameters from 10 in. to 

96 in.  (254 mm to 2.44 m)  and 

provides high levels of repeatability 

for faster measurement-taking to 

help reduce overhaul alignment 

times by up to 50 percent.  The 

fixture uses  two fixed-length legs 

approximately equal to the radius of 

the bore, one leg with a measuring 

tip and one for support. 

 

 

 

 

 

 

Figure 5 – 

A-1511 Wand Bore Fixture 

Содержание L-705

Страница 1: ......

Страница 2: ...icles of equipment manufactured by other companies and limited by a warranty extending for less than one year In such an event the more limited warranty applies to said instrument or article of equipm...

Страница 3: ...ac Man Magnets 7 Using the T 218T 2 Axis Turbine Target 14 Measuring Bores Using the A 1511 Wand Bore Target R 1308 Readout 16 Calculating the Bore Misalignment 18 Measuring Bores Using the A 1511 Wan...

Страница 4: ...he two micrometers on the back of the L 705 These micrometers are adjusted until the reference target reads zero both vertically and horizontally The laser is now set up and ready for measurements For...

Страница 5: ...ly following the NORMIN procedure described in Appendix A accuracies of 0002 in 0 005 mm in 10 ft 3 m can also be achieved The L 705 has a range of 50 ft 15 m and under good environmental conditions i...

Страница 6: ...05 Laser The L 705 Laser beam is factory adjusted to be concentric to the mounting diameters 2 25 in or 57 15 mm and 75 in or 19 05 mm within 0005 in 0 0127 mm With the adjusting micrometers set at th...

Страница 7: ...on the micrometer control at the apex of the V and H axis arrows Insert the plug gently until it snaps into place Replacing the Batteries The battery pack uses two 9 volt batteries The batteries are h...

Страница 8: ...reference bores Since the data is live the diaphragm can be adjusted until the reading is zero or to an offset determined by the engineers Figure 4 T 218 Target A 1511 Wand Bore Fixture The A 1511 Wa...

Страница 9: ...1308 Single Axis Readout The R 1308 Single Axis Readout is a small lightweight readout that attaches to the base post of Hamar Laser s A 1519 2 4ZB Wireless Targets and connects directly to the targe...

Страница 10: ...ck out machines for stationary procedures If a machine is running set up barriers and or warning signs and route all cables away from moving parts Clean and check all equipment fixtures and mounting s...

Страница 11: ...to absorb any angularity that may occur when tightening the set screws against the angle iron Tighten the set screw in the rotating slot magnetic mount against the angle iron Place one of each of the...

Страница 12: ...iron and onto the second length of angle iron Use a measuring tape to center the A 502L with the bore from side to side The magnetic mounts are designed so that the A 502L will be very near to the cen...

Страница 13: ...d the reference bore Place the tip onto the bore surface so it will hold the rod from falling out The Bore Sweep Unit has a linear bearing slide so the rod cannot rotate when it is inserted into the u...

Страница 14: ...the A 502 in the bore according to the desired offsets determined by the shaft centerline Note The adjustment knobs are only push adjustments One knob must be loosened and the opposite knob tightened...

Страница 15: ...sired set point if necessary If any adjustment is made the Digital Dial Indicator must be e re zeroed at the original set point Move the Bore Sweep Rod tip to the bottom of the bore Position the A 502...

Страница 16: ...t the angle iron in the straight slot magnetic mount Tighten the set screw in the rotating slot magnetic mount Using a measuring tape position the A 502 onto the angle iron horizontally near the cente...

Страница 17: ...zontally by turning the vertical and horizontal adjustments on the front of the L 705 laser If the laser beam is not going into the front opening of the T 218T 2 Axis Turbine Target it may be necessar...

Страница 18: ...15 Half Bore Alignment Setup...

Страница 19: ...he R 1307 Readout for dual axis mode see Appendix B beginning on Page 24 Using a measuring tape measure the diameter of the bore Select the appropriate legs and or extensions that can be adjusted to t...

Страница 20: ...ou get the highest number reading on the readout When you have the highest number reading on the readout press the ABS REL Button on the front of the R 1308 Readout to zero the reading Rotate the targ...

Страница 21: ...eep the target in and out until you get the highest number reading on the readout Record that number on the sheet of paper Calculating the Bore Misalignment Left side of bore target reading 000 Right...

Страница 22: ...e the measuring tip on the side of the bore so it is resting on the support leg Adjust the support leg until the horizontal reading on the R 1307 readout is less than 030 in 0 77mm Adjust the measurin...

Страница 23: ...less than 030 in 0 77mm Slowly sweep the target in and out until the highest number displays on the R 1307 Readout Record that number on a sheet of paper Note Be sure to note whether the number is po...

Страница 24: ...sitive or negative Repeat this procedure in each of the components to be measured Calculating the Bore Misalignment Left side of bore target reading 000 Right side of bore target reading 026 The bore...

Страница 25: ...re alignments the True Bore Center the Target Center and the Laser Reference Centerline If mounting fixtures were perfect the Target Center would be located at the True Bore Center and if perfectly al...

Страница 26: ...n the readout are also rotated Therefore although the Target Center appears to be to the right of and lower than the Laser Beam Center in Figure 10 the vertical readings are positive and the horizonta...

Страница 27: ...24 Appendix B Configuring the R 1307 2 4ZB Readout Model R 1307 Readouts Control Panel...

Страница 28: ...types TGT 0 for HLI use only Do not use TGT nn P 10 10 10x10 mm sensor pulsed beam mode TGT nn F 10 10 10x10 mm sensor fixed beam mode TGT nn P 4 4 4x4 mm sensor pulsed beam mode TGT nn F 4 4 4x4 mm s...

Страница 29: ...stem ID dial on the side of the target is set to 1 7 Press the Menu button until displays in the Vertical Display window Use the up or down arrow keys until displays in the Horizontal Display window A...

Страница 30: ...the type intended for nail polish removal NOTE When cleaning precision optics even with the best quality optical cleaning tissue use gentle pressure to avoid scratching the surface or damaging the opt...

Отзывы: