18 June 2016
X6-ElectroMod
A 160AH 1.5KW Electrical Power Generator for the BMW X6
pg. 27
Copyright © 2016, HallonPower. All content and images presented on this website are copyrighted © and all rights are reserved.
All manufacturer names, symbols, and descriptions, used in our images and text are used solely for identification purposes only. It is neither inferred nor
implied that any item sold here, is a product authorized by or in any way connected with any vehicle manufacturers displayed on this page. This document
may be modified at any time and without notice.
Powering ON & Systems Check
CAUTION: To proceed with this section, the previous section must have first been completed.
1.
Make sure the car engine is switched OFF and all CBs are OFF.
2.
Start Battery Voltage meter:
a.
Check the SCP and make sure the Start Battery Voltage meter is
reading the main Alternator Battery.
3.
Smartgauge:
a.
Check the Smartgauge and make sure you can read both main
and service batteries.
4.
LED Switch
a.
Pushing the LED button on the SCP switches ON/OFF the
illuminating LED in the handle of the flap, as well as the LED in the
Start Battery Voltage meter.
5.
Inverter (Critical Consumers):
a.
Make sure the 3-way switch on the back of the inverter is in the
‘REMOTE’ position.
b.
Switch ON CB#7 for the inverter.
c.
On the SCP, press the ON/OFF switch on the CR-6 inverter
remote. You should see the remote indicate that the inverter has
been turned ON.
d.
Try plugging a device in the AC outlet and see if it works. The AC
outlet should provide information on the amount of power
consumed.
e.
When satisfied, press the ON/OFF switch on the CR-6 inverter
remote again, to turn the inverter OFF.
f.
Finally Switch OFF CB#7.