![Halcyon H50-01-NG Скачать руководство пользователя страница 52](http://html1.mh-extra.com/html/halcyon/h50-01-ng/h50-01-ng_installation-operation-and-owners-manual_3306278052.webp)
Halcyon
Gas Fireplace European
Home
.com
52
Appendix A - LP Gas Conversion
Regulator Cap (LP)
Figure A5 - Gas Valve (LP)
Figure A6 - Close-up of Regulator Cap Set to LP
Figure A7 - Close-up of Regulator Cap Set to “NAT”
11. Unscrew the Regulator Cap, turn it over and screw it back in with the recessed end marked “LP” exposed. See
Figures A5 and
A6. Figure A7
shows the Regulator Cap before it has been reversed to LP.
12. Write the conversion date and the name and address of the company or person doing the conversion on the LP Conversion
Label. Peel the backing off the label and affix it to the bottom plate of the Burner Assembly, next to the gas valve as shown in
Figure B8
.
13. Re-install the Burner Assembly.
14. Test the entire gas train for leaks using a ‘sniffer’ or non-corrosive leak detection fluid.
15. Replace the Glass Panel Assembly.
16. If the Fireplace installation is complete then test for proper pressures, flame pattern and operation otherwise return to the
appropriate section of the Installation, Operation and Owner’s Manual and complete the installation.
Retain the removed parts if the Halcyon Gas Fireplace is to be re-converted for use with natural gas.