PRE-INSTALLATION PLANNING
Table 3,
below, lists the minimum dimensions of the rough opening
(shown in
Figure 7
) into which the Halcyon Gas Fireplace is set. It also
lists the minimum height of an enclosure (W) and the minimum distance
between a room ceiling and the bottom of the Halcyon (V).
Figure 8
shows the relationship between a room ceiling (V) and an
enclosure (or chase) ceiling (W).
S
U
T
Figure 7 - Rough Opening
S
Rough Opening Width
57”
T
Rough Opening Height
44”
U
Rough Opening Depth
18½”
V
Minimum Height to Chase Ceiling 57½”
W
Minimum Height to Room Ceiling
44”
Table 3 - Minimum Dimensions
Figure 8 - Minimum Enclosure Height and Distance to Ceiling
V
W