MAINTENANCE
To keep your Halcyon Gas Fireplace in peak condition, routine inspection and maintenance should be performed by a qualified
service person. We recommend that this be done prior to the beginning of your heating season.
ANNUAL INSPECTION and CLEANING
1. Remove the glass panel and clean the pilot burner and main burner of any soot, dust or any other build-up. Clean the Flame
Sensor of any corrosion or build-up.
Figure 36
shows proper pilot burner operation and
Figure 35
shows proper main burner
operation.
2. Inspect the Crushed Glass Burner Media for soot build-up. If excessive soot is present, have a qualified service person inspect
the unit for proper combustion. Carefully clean the Crushed Glass Burner Media with a brush.
3. Check that the vent pipe and termination cap are free from obstructions such as nests, leaves or debris. Ensure that the
venting is tight and sealed.
4. Confirm that the frame, glass and gasket are free from damage including scratches, cracks and misalignment. Check the
latches for proper alignment and engagement. If it is necessary to replace the glass assembly, use only the H50-SA-GP-01
Glass Panel Assembly from European Home.
5. Ensure that the Fireplace is ready for operation, light the Fireplace and check both the pilot burner and main burner for
proper flame size and operation.
Figure 35 - Main Burner
Figure 36 - Pilot Burner
Before doing any maintenance work turn off both the gas supply and electric supply then allow the entire Fireplace to cool
completely.
Do NOT clean the glass when it is hot!
WARNING
Flame
Sensor