05-1481-00-00.fm
227
Maintenance and servicing
5.18.6 Checking the suction mouth sealing strips (3-brush system)
Observe the Safety instructions – Vacuum sweeping system, see page
222. Check the sealing strips
of the suction mouth at regular
intervals. Maintenance intervals according to maintenance plan,
see page 167.
Immediately replace defective seals, also on the coarse material
flap
, since the suction power is reduced.
The sealing strips must have a ground clearance of 5 +0/-2 mm and
15 +0/-2 mm at the front and at the rear respectively. The
coarse material flap is set to a ground clearance of 20 +0/-2 mm.
Loosen the wheel holders
in order to set the sealing strips.
Note
PU sealing strips (option) must have a ground clearance of
3 +0/-2 mm and 7 +0/-2 mm at the front and at the rear
respectively.
Fig. 185:
A
B
3 +0/-2 mm
15 +0/-2 mm
C
C
C