The HAKKO FG-102 does not operate even when the power switch is turned ON.
:
Is the battery attached in the battery box?
:
Set the batteries.
:
The orientation of the battery is correct?
:
In accordance with the display of the battery box, please put in the correct orientation.
:
The battery is not outdated.
:
Please replace with a new battery.
Displays the burnout when it is hit with the tip of the soldering iron.
:
Sensor is disconnected from the terminal?
:
Please attach to the terminal sensor.
:
Do not put in reverse the sensor?
:
Please attach in the correct orientation sensor.
Can not read the ID.
:
Connector of the bar code reader is disconnected?
:
Please be attached to the connector body.
:
NG lock function or does not have the ON?
:
Do continue the measurement ID became NG until receive the OK determination, please
turn OFF the function.
Displayed "The port is not assigned,"
:
Do you have already connected the PC and the body?
:
After closing once the software, please reconnect the USB cable.
:
Is there a mistake on the setting of the port number?
:
Check the port number from Device Manager, please set again.
Displayed "data. Invalid,"
:
After closing once the software, please reconnect the USB cable.
7.
ERROR DISPLAY
8.
TROUBLESHOOTING GUIDE
34
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
CHECK
ACTION
ACTION
S y s t e m
e r r o r
System error display
When an abnormality is detected in the
hardware and displays.