16
4. After the temperature measurement, press the REC button to save the data on the unit main body.
* The unit can save up to 300 records of data. Any data saved beyond the 300 records overwrite
the existing records starting at the first record.
* After the recording, if the unit ID that has been read is registered in a group and the upper/lower
temperature limit is exceeded, the following failure screen will be displayed. The display of the
temperature value will be inverted. Pressing the button will cause the return to the record
mode screen.
* If the Fail-proof
function is set ON, once a failure is determined, no unit ID other than those failed
will be accepted from the next time onward.(
Refer to P27
)
P r e s s b u t t o n
F a i l e d
Fail
O u t o f t e m p
s e t t i n g r a n g e
P r e s s b u t t o n
455
℃
3. Measure the temperature. The following shows the temperature measurement procedure in
the recording mode.
1) Put the iron tip into contact with the sensor. When the temperature rises, the HOLD icon
starts blinking.
2) As the temperature stabilizes, the blink will stop and the recording will be enabled.
(Please note that it is no more than a rough indication for a guide.)
R
H
001
Temp
Gp
Meas
ID
U n i t
ID
xx
00001
00001
250
℃
Date
2014/08/31/14:01
Hold icon blinking screen
blinking
CAUTION
If you get the iron tip off the sensor before the stop of the HOLD icon blinking, it will cause a
tip end-off error, disabling the recording. Allow sufficient time after the stop of the blinking
before getting the iron tip off the sensor.
Iron tip end-off error screen
Failure display screen