OPERATING MANUAL  

  

FOR 

AGRI-THERM II

 HANDHELD DIFFERENTIAL THERMOMETER 

 

MODEL 6110.4ZL 

 

TEMPERATURE RANGE: 

-40°C to 100°C  or -40°F to 212°F 

 

 

Physical Address: 1891 North Oracle 

 

Tucson, AZ 85705-6444 

Mailing Address:  P. O. Box 5276 

 

Tucson, AZ 85703-0276  

Telephone:  (520) 792-4545 

 Fax (520) 792-4546 

 

Toll Free:  (800) 422-4342 

E-mail: 

info@

EVEREST

Interscience.com

   

Website:  

www.

EVEREST

interscience.com

  

   
 

Summary of Contents for 6110.4ZL

Page 1: ...MPERATURE RANGE 40 C to 100 C or 40 F to 212 F Physical Address 1891 North Oracle Tucson AZ 85705 6444 Mailing Address P O Box 5276 Tucson AZ 85703 0276 Telephone 520 792 4545 Fax 520 792 4546 Toll Free 800 422 4342 E mail info EVERESTInterscience com Website www EVERESTinterscience com ...

Page 2: ...ttings 6 2 5 Surface Temperature Measurement 6 2 6 Temperature Differential Measurement 6 2 7 Ambient Temperature Measurement 6 2 8 Signal Output 7 3 THROUGH THE LENS INTRA OPTICAL LIGHT SIGHTING 3 1 TTL Intra Optical Light Sighting 8 3 2 Focusing with the VARIO ZOOOM 8 Chapter 4 AGRI THERM II SPECIFICATIONS 4 1 Model 6110 4ZL Specifications 10 Chapter 5 MAINTENANCE 5 1 General 11 5 2 Cleaning 11 ...

Page 3: ...ture etc cannot be ascertained by the operator It is very important for the operator to know where all parts of the target spot are located because if any part of the spot is off the edge of the target surface serious reading errors will occur The Everest TTL Through The Lens Intra Optical Light Sighting System Patent No 4 494 881 solves this problem as explained in Chapter 3 of this manual The Mo...

Page 4: ... AGRI THERM II Infrared Thermometer 2 A Carrying Case W 3 A Battery Charger 4 A Signal Output Cord 5 A Certification of Calibration 6 An Operating Manual If any items are missing or appear to have been damaged during shipment please save the shipping box and notify Everest Interscience immediately at 520 792 4545 Toll Free at 800 422 4342 or by E mail to info EVERESTInterscience com ...

Page 5: ...rging is complete unplug the AC adaptor from the outlet and then remove the plug from the instrument 2 2 ABBREVIATIONS ON REAR PANEL he abbreviations on the Rear Panel of the AGRI THERM II stand for the following T 9 SEL Select IR DIFF or AMB 9 IR Infrared Surface Temperature Reading This is the current infrared surface temperature reading of the target that the instrument is focused on 9 DIFF Tem...

Page 6: ...he Temperature Differential Patent No 4 301 682 between the target temperature and the dry bulb ambient air temperature first press the SEL button the number of times necessary until the light is shown above DIFF Then pull the antenna out of the front of the instrument This removes the sensor on the end of the antenna from the heating and cooling effects of the instrument and the operator s hand N...

Page 7: ...The instrument is provided with a signal cord to connect to a data logger through this receptacle No data is stored in the infrared thermometer itself The DATA connection provides for the capability of running the AGRI THERM II continuously and sending the data to an outside source where the analog signal can be converted to a digital signal and the data can be logged and saved T 7 ...

Page 8: ...out of alignment It will always illuminate the area where the infrared visible optics are focused W 3 2 FOCUSING WITH THE VARIO ZOOOM n order to focus on a smaller or larger area the front of the Vario Zooom Patent Pending infrared thermometer need only be pushed in or out until the target is completely illuminated Simply point the instrument at a target in subdued ambient light and push the front...

Page 9: ...g in a laboratory There you will be able to see the light being emitted by the Light Emitting Diode LED and determine the distance to spot size ratio Then when you are in the field you can determine the area being measured by knowing that the ratio of the distance to spot size will remain constant as it was in the lab ...

Page 10: ...s Field of View FOV Illumination Source Light Emitting Diode SAFE NO LASERS Focus Variable from 2º to 20º with Vario Zooom Patent Pending Display Numeric on Liquid Crystal Display on Rear Panel OPERATING CONDITIONS Operating Environment 20 C to 65 C or 14 F to 150 F up to 99 Relative Humidity Non Condensing Storage Temperature Same as Operating Environment Temperature GENERAL Response Time 1 Secon...

Page 11: ...orization RMA No You can also request the RMA by E Mail to info EVERESTInterscience com or an RMA form can be obtained on our website at www EVERESTInterscience com After receiving the RMA No please ship the instrument insured freight prepaid to EVEREST INTERSCIENCE 1891 North Oracle Road Tucson AZ 85705 6444 USA Please include an explanation of the problem or problems you are having or the servic...

Page 12: ...re commencing repair The customer must provide a Purchase Order or credit card information in the amount of the repair and return shipping before work will commence After Everest has sent the repair quotation the customer has up to one year to provide a Purchase Order or credit card information to Everest for either the repair and return or the return only of the instrument If the customer does no...

Page 13: ...STInterscience com It is necessary to send a check in the amount of the Evaluation Analysis Fee along with the instrument This charge can be obtained on our RMA form on the website or by calling 800 422 4342 or 520 792 4545 We apologize in advance if you do have a problem with one of our instruments We will call you when we receive the instrument and before commencing any work on the instrument if...