Where to Locate The
Series 96
Where you will locate the Series 96 depends on what other water treatment
equipment you currently have installed. The Series 96 should be located:
After
:
Before
:
Water Meter
Water Heater
Pressure Tank
TYPICAL 96 SERIES INSTALLATION
Figure 1
Keep in mind that you need to have a drain available nearby for waste water.
In placing the Series 96, consider the following:
Install the Series 96 ahead of the water heater to prevent build-up of hard
water deposits in the water heater. This placement will maintain the water
heater efficiency.
Install pressure reducing valve if inlet pressure exceeds 90 psi (620 kPa).
A minimum of 10 feet (3 m) of 3/4" (19 mm) pipe from the outlet of the
water conditioner to the inlet of the hot water heater is recommended to
reduce the potential for hot water back flowing into the valve.
•
•
•
Series 96 Owner’s Manual
6