background image

15 YEAR LIMITED RESIDENTIAL WARRANTY

Series 96 Owner’s Manual

36

TO PLACE THE EQUIPMENT UNDER WARRANTY, THE 
WARRANTY REGISTRATION CARD MUST BE COMPLETED
AND RETURNED BY THE ORIGINAL OWNER TO HAGUE 
QUALITY WATER INTERNATIONAL WITHIN 30 DAYS OF
INSTALLATION.

Coverage

This warranty covers the Hague Maximizer® System delivered to the 
original owner when the system is purchased for personal, family, or
household use. It is intended to cover defects occurring in workmanship
or materials or both.

Warrantor's Performance and Length of Warranty

Hague Quality Water International warrants that upon receipt from the
original owner of any Hague Media Tank, Brine Tank or Valve Body
found to be defective in material or workmanship, Hague will repair or
replace the defective item, at no charge for that item, for 15 YEARS
from date of installation.

Hague Quality Water International further warrants that upon receipt
from the original owner of any other mechanical or electronic parts, and
the fine mesh polystyrene resin, which are found to be defective in 
material or workmanship, Hague will repair or replace the defective
parts, at no charge for those parts for 3 YEARS from date of 
installation; and thereafter will repair or replace the defective parts only
upon receipt of payment by the original owner of the following 
percentages of the then current list prices for the parts:

All defective parts must be returned, along with the equipment serial
number and date of original installation, to an authorized Hague dealer
or Hague Quality Water International PREPAID, and replacement parts
will be returned by Hague to the original owner FREIGHT COLLECT.

Further Exclusions and Limitations on Warranty

THERE ARE NO WARRANTIES OTHER THAN THOSE
DESCRIBED IN THIS WARRANTY INSTRUMENT.

This warranty does not cover any service call or labor costs incurred
with respect to the removal and replacement of any defective part or
parts. Hague Quality Water International will not be liable for, nor will 
it pay service call or labor charges incurred or expended with respect to
this warranty.

Years from Installation

% of list price 

to pay

3-4

50%

4-5

55%

5-6

60%

6-7

65%

7-8

70%

8-9

75%

9-10

80%

over 10

100%

In the event the water supply being processed through this product 
contains bacterial iron, algae, sulphur, tannins, organic matter, or other
unusual substances, then unless the system is represented as being 
capable of handling these substances in the system specifications, other
special treatment of the water supply must be used to remove these 
substances before they enter this product. Otherwise, Hague Quality
Water International shall have no obligations under this warranty.

This warranty does not cover damage to a part or parts of the system
from causes such as fire, accidents, freezing, or unreasonable use,
abuse, or neglect by the original owner.

This warranty does not cover damage to a part or parts of the system
resulting from improper installation. All plumbing and electrical 
connections should be made in accordance with all local codes and the
installation instructions provided with the system. The warranty does
not cover damage resulting from use with inadequate or defective
plumbing; inadequate or defective water supply or pressure; inadequate
or defective house wiring; improper voltage, electrical service, or 
electrical connections; or violation of applicable building, plumbing, or
electrical codes, laws, ordinances, or regulations.

THIS WARRANTY DOES NOT COVER INCIDENTAL, 
CONSEQUENTIAL OR SECONDARY DAMAGES.

ANY IMPLIED WARRANTIES ON THE PRODUCT DESCRIBED
IN THIS WARRANTY WILL NOT BE EFFECTIVE AFTER THE
EXPIRATION OF THIS WARRANTY.  NO DEALER, AGENT,
REPRESENTATIVE OR OTHER PERSON IS AUTHORIZED TO
EXTEND OR EXPAND THIS LIMITED WARRANTY.

Some states do not allow limitations on how long an implied warranty
lasts or the exclusion or limitation of incidental or consequential 
damages, so the above limitations and exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have
other rights which vary from state to state.

Claims Procedure

Any defects covered by this warranty should be promptly reported to
Hague Quality Water International at 4343 South Hamilton Road,
Groveport, Ohio 43125. In writing about the defects, please provide the
original owner's name, telephone number, and original address; serial
number and model number of the product; date of purchase; and name
of dealer from whom purchased. Hague Quality Water International
reserves the right to replace defective parts with exact duplicates or
their equivalent.

For Owner's Reference

Model No.

Equipment Serial No.

Installation Date

Installer’s Signature

Independent Dealership Name

Independent Dealership Address

Содержание 96MM

Страница 1: ...Series 96 Owner s Manual REV 2 0...

Страница 2: ...MENTS HOW AND WHEN TO USE THE BYPASS 14 TROUBLESHOOTING 15 PARTS DIAGRAMS 17 Brine Valve Elbow Installation 32 Brine Cabinet Data 33 CYCLE SETTINGS 34 EQUIPMENT SPECIFICATIONS 35 WARRANTY 36 Page Inst...

Страница 3: ...lved minerals are calcium and magnesium the water is said to be hard Hard water often also contains traces of dissolved iron dirt and sediment particles Although hard water is not harmful to drink it...

Страница 4: ...um chloride you must select the potassium option during the programming of the controller We do not recommend the use of Potassium Chloride when iron is present in the raw water supply Disinfection Th...

Страница 5: ...ur water conditions and the number of people in your family If your electricity is out longer than 17 hours please reset time of day All other settings will be maintained For information on programmin...

Страница 6: ...sed through this product has a compensated hardness of more than 90 grains per gallon or contains bacteria iron bacteria tannins algae oil acid salt or other unusual substances special equipment must...

Страница 7: ...96 Building Codes All installations must conform to local plumbing and electrical codes Minimum Inlet Pipe Size Well water recommended minimum inlet pipe size 3 4 I D 19 mm Municipal water recommended...

Страница 8: ...waste water In placing the Series 96 consider the following Install the Series 96 ahead of the water heater to prevent build up of hard water deposits in the water heater This placement will maintain...

Страница 9: ...ss soldering flux air or any other foreign material 9 Close the faucet and check for leaks If leaks are found turn off the main water supply and open the nearest cold water faucet to depressurize the...

Страница 10: ...enerate when it reaches the REG TIME Also as a safety feature if the appliance s capacity is exceeded a demand immediate regeneration will occur This way a family should never run out of soft water an...

Страница 11: ...n to move cursor one digit to the right of parameter that can be set When cursor is at extreme right position press again to reset cursor to extreme left position DISPLAY FUNCTION When pressed and hel...

Страница 12: ...arameter The display will show Soft V 1 07 This parameter may not be set 3 00 Push the DISPLAY button to step to the next parameter The display will show Mode 2 The Mode is the number of the OPERATING...

Страница 13: ...9 00a Push the CHANGE button to toggle parameter value from No to Yes In this example set to 96hr Regen No 10 00 Push the DISPLAY button to step to the next parameter The display will show Backwash 1...

Страница 14: ...ample set to Turbine Test NO 15 00 Push the DISPLAY button to step to the next parameter The display will show Reg Tonight NO This parameter if set to YES will force a regeneration at the next set reg...

Страница 15: ...ple 11 00 AM or 05 00 PM 2 00 Push the DISPLAY button to step to the next parameter The display will show Reg Time 02 00 AM This parameter is to be set for the desired time a normally scheduled regene...

Страница 16: ...preference over a period of time WHEN HOW TO USE THE BYPASS VALVE The bypass valve is intended to provide isolation of the Series 96 appliance in the event of a system malfunc tion leak or if the use...

Страница 17: ...ms an empty space between the water and salt To test use a blunt object like a broom handle Push the handle into the salt to dislodge the salt bridge No soft water The plumbing bypass valve is in the...

Страница 18: ...g 8 Excess water in brine tank Restricted frozen or pinched drain line See Fig 1 Remove restriction thaw or straighten drain line Plugged brine line brine line flow control or air check See Fig 9 11 C...

Страница 19: ...1 1 54501 Media Cabinet Cover Assembly 2 2 90837 Bypass Nut Gasket 3 2 90254 1 or Copper Adapter 2 90256 PVC Adapter optional 2 90258 1 Copper Adapter optional 4 2 90251 Bypass Nut 5 1 CO700A Cabinet...

Страница 20: ...SERIES 96 BRINE TANK ASSEMBLY Series 96 Owner s Manual 18 For brine tank information on water depth and salt usage see page 34 Figure 4...

Страница 21: ...2 93870 4 Screw 3 90614 1 Drain End Cap Assembly 4 93808 2 O Ring 5 93835 2 Sleeve 6 93838 2 O Ring 7 90615 94 1 Bypass Assembly 8 93833 1 Cord Clip 9 90828 1 O Ring 10 not used 11 95301T JG 1 Drive...

Страница 22: ...opening The gasket seals at its outer edges and between the inlet screen and nozzle opening These areas must be free of defects such as tearsor pits and be free of debris 3 93221 1 Injector Nozzle Cre...

Страница 23: ...together and seals the assembly to the Main Valve Body 6 90807 4 Injector Screw These four machine screws should be tightened evenly and snug 7 93810 1 Injector Screen Acts as a pre filter to keep deb...

Страница 24: ...27 O Ring 8 1 90246 Bypass Housing 9 1 90616 Bypass Piston Assembly 10 1 90218 Bypass Piston Drive Shaft 11 1 90803 O Ring NO QTY PART NO DESCRIPTION 12 1 90263 Bypass Endcap right 13 1 90828 O Ring 1...

Страница 25: ...e in the End Cap This groove must be free of defects such as pits or scratches and also free of debris When assembling the End Cap to the Housing care should be taken to make sure that the O ring stay...

Страница 26: ...k wafer Hall Effect Sensor to the controller board must not be severely bent folded over cut or broken Care should be taken when putting the Sensor into the Sensor Housing The spring flap below the Se...

Страница 27: ...2 1 90217 Drive Motor 3 2 93891 Hex Nut 4 1 93238 Drive Gear 5 2 90809 Screw 6 1 93219 Piston Slide Cam Cover 7 1 93217 Piston Slide Cam 8 1 93583 Drive End Cap 9 1 93216 Piston Slide 10 2 90818 Screw...

Страница 28: ...freely before the Drive Motor is assembled 93219 1 Piston Slide Cam The cover secures the Piston Slide Cam Part No 93217 in place and acts as a Cover bushing for the Cam Shaft 95521 1 Magnet Disc The...

Страница 29: ...Figure 9 NO QTY PART NO DESCRIPTION 1 1 93620 Piston Assembly includes O Ring Spring 2 1 90821 O Ring 3 1 93260 Housing 4 1 93254 Quad Ring Retainer 5 1 90843 5 gpm Flow Control 6 1 93805 O Ring 7 1 9...

Страница 30: ...ressure insert the Cap CAUTION the 3 8 locking ring 9 must be installed to prevent air from being drawn into the appliance during brine rinse 93620 1 Brine Piston The Piston should have an O Ring on t...

Страница 31: ...seal areas are kept clean and free of debris Also both O rings should be in the proper locations one under the flange and one in the groove Do not overtighten the Fill Plug when assembling When the fl...

Страница 32: ...lus or minus 10 backwash flow rate at varying H2086 3 0 Control Button pressures Care should be taken when replacing Drain Line Flow Control Buttons to ensure that the correct rate is being used for a...

Страница 33: ...SERIES 96 SAFETY SHUTOFF ASSEMBLY Series 96 Owner s Manual 31 Figure 11...

Страница 34: ...sleeve are a 3 piece assembly that can come apart if removed from the elbow body Parts must be re assembled exactly as shown to function properly When connecting the 3 8 polytube it is first necessary...

Страница 35: ...hs correlate to the amount of salt used per regeneration SALT lbs DEPTH inches 1 0 5 3 4 3 0 8 7 8 6 0 11 7 8 9 0 15 3 8 To maintain peak performance of your appliance it is recommended that you inspe...

Страница 36: ...ing Service Setting English Unit Hardness Setting Number ______ Iron ppm clear water Capacity in Grains 24 480 Backwash 1 minute 03 0 Brine Rinse minute 30 0 Backwash 2 minute 01 0 96 Hour Regeneratio...

Страница 37: ...gpm at 10 psi pressure drop 30 2 lpm at 68 9 kPa pressure drop Minimum water temperature 40 F 6 C Maximum water temperature 120 F 49 C Min Max ambient temperature 40 F 120 F Plumbing connection 3 4 or...

Страница 38: ...tains bacterial iron algae sulphur tannins organic matter or other unusual substances then unless the system is represented as being capable of handling these substances in the system specifications o...

Страница 39: ...Series 96 Owner s Manual 37...

Страница 40: ...ng as the unit is softening the water Test product water every 12 months with the hardness test strips to check for proper functioning Hague Quality Water International 4343 S Hamilton Rd Groveport OH...

Отзывы: