RE 15345-WA, Version 11.2022, Bosch Rexroth AB
Maintenance and repair |
Drive system Hägglunds Fusion 51/72
Frequent checks
Unusual vibrations or noises
Fluid leaks
Fluid level in the tank
The unit is clean
The air flow paths are not blocked
Pressure levels normal - stable
Actuator speeds normal - stable
Operating temperature
The drive is running smoothly
Contamination indicators on the filters
Check and clean the oil pan
Scheduled maintenance
Planned maintenance at specific time intervals, including the following checks and
actions:
All points under frequent checks
Check all pressure levels
Check for stable temperature levels around the system
Drain water and sludge from the tank at the drain tap
Check the electric motor
Check the function of monitoring equipment/switches, etc
Cleaning.
NOTICE
High pressure washing
Damage on equipment
f
Never use a high pressure washing system to clean inside the drive system
Check the cables
Check drain line flows and drain line oil condition
Check the hoses, couplings and pump, with respect to cracks, leakages and
condition
Check the shaft coupling through the inspection hole.