RE 15345-WA, Version 11.2022, Bosch Rexroth AB
Installation |
Drive system Hägglunds Fusion 37/72
7.6 Electric connections
NOTICE
The system will not fullfill the functionallity
Damage to the customer equipment
f
Installation of electrical equipment must in most countries be installed by
licensed electricians (ref. to domestic laws)
f
All electric equipment has to be installed and used by qualified personnel who
are familiar with relevant safety requirements and domestic laws.
f
Personal protective equipment necessary for the prevention of accidents at
the mounting and operating site shall be provided in accordance with the
regulations prevailing in the local country.
f
Grounding shall be carried out according to local regulations before the
electric equipment is connected to the main voltage. Grounding point is on the
side of the frame see
f
All electrical supply levels must be within the limits that the equipment is
constructed for, see order specific Hägglunds Fusion documentation and rating
plates.
7.6.1 Control system
All external electrical connections must be connected according to the electrical
drawings in the order specific Hägglunds Fusion documentation.
7.6.2 Air-oil cooler
The main voltage and connection are marked on the electric motor marking plate. Y
or D Connection is done depending on supply voltage in accordance to
MCC (Motor Control Center). The start and stop signal to control the MCC shall be
connected according to the order specific Hägglunds Fusion documentation. Check
direction of rotation, see air stream arrow in
Air flow
Fig. 17:
Air-oil cooler
DD00073642