48/72
Hägglunds Fusion Drive system
| Commissioning
Bosch Rexroth AB, RE 15345-WA Version 11.2022,
Fig. 26:
Setting pressure compensator
3. Pressure compensator (pressure cut-off) setting
Measure the working pressure in both the MA and MB port
Release the lock nut and adjust the setting screw. The pressure compensator
shall be adjusted with blocked main-port or blocked actuator. Stroke the pump
to about 50% of max flow. Set the compensator pressure to a value according
to the order specific Hägglunds Fusion documentation.
4.
Manual control of flow on A4VG pump
The A4VG pump flow can be controlled manually with a button on each side of
the pump controller. The manual control must be handled with high precaution
as this will override all interlock of the drive.
CAUTION
Manual control of pump
Risk of personal injury or damage of epuipment
f
Use with high precaution