RE 15345-WA, Version 11.2022, Bosch Rexroth AB
Scope of delivery |
Drive system Hägglunds Fusion 19/72
5.5
Requirements for hydraulic fluid cleanliness
The drive systems are equipped with a filter in the charge line. In order to
obtain stated service life it is important to follow recommendations concerning
cleanliness levels and maintenance.
Cleanliness level recommendations
•
When filling the system with hydraulic fluid it is important to fill through the
dedicated oil filling connection (see
8.2: Filling up the system with hydraulic fluid
).
•
For industrial applications the contamination level should not exceed ISO
4406:1999 18/16/13.
•
Have a water content of <200 ppm (0,02%).
•
Always use filter elements recommended and supplied by Bosch Rexroth.
•
The hydraulic fluid should be analysed according to the maximum intervals on
the maintenance chart (see
). Be particularly careful
when removing equipment for repairs or maintenance, dirt must not be allowed
to enter the system, clean prior to opening and plug open connections.
NOTICE
Dirt in oil
Damage on equipment.
f
Do not re-use hydraulic fluid which has leaked out.
About this produkt