ModBUS Register Information
62
Setup/Relay 1/Control
Phase
40067
Unsigned
Integer
1
R/W
Sets the controller phase
(0 = Low; 1 = High)
Setup/Relay 1/Control
Deadband
40068
Float
2
R/W
Sets the controller deadband
Setup/Relay 1/Control
Overfeed
Timer
40070
Unsigned
Integer
1
R/W
Sets the overfeed timer value (mins)
Setup/Relay 1/Control
On Delay
40071
Unsigned
Integer
1
R/W
Sets the on delay time (sec)
Setup/Relay 1/Control
Off Delay
40072
Unsigned
Integer
1
R/W
Sets the off delay time (sec)
Setup/Relay 1/Control
Reset
Overfeed
Timer
40073
Unsigned
Integer
1
R/W
Resets the overfeed timer
Setup/Relay 1/Event
Setpoint
40074
Float
2
R/W
Sets the event setpoint
Setup/Relay 1/Event
Phase
40076
Unsigned
Integer
1
R/W
Sets the event phase (0 = Low; 1 = High)
Setup/Relay 1/Event
Deadband
40077
Float
2
R/W
Sets the event deadband
Setup/Relay 1/Event
On Max Time
40079
Unsigned
Integer
1
R/W
Sets the max on time (mins)
Setup/Relay 1/Event
On Min Time
40080
Unsigned
Integer
1
R/W
Sets the min on time (mins)
Setup/Relay 1/Event
Off Max Time
40081
Unsigned
Integer
1
R/W
Sets the max off time (mins)
Setup/Relay 1/Event
Off Min Time
40082
Unsigned
Integer
1
R/W
Sets the min off time (mins)
Setup/Relay 1/Timer
Hold Type
40083
Unsigned
Integer
1
R/W
Sets which Sensor outputs are affected
during timer on time (0 = None;
2 = Selected Sensor; 13 = All Sensors)
Setup/Relay 1/Timer
Sensor Select
40084
Unsigned
Integer
1
R/W
Selects which Sensor outputs are being
held/transferred during the timers on time
(this is used when Hold type is set for
single Sensor)
Setup/Relay 1/Timer
Hold Mode
40085
Unsigned
Integer
1
R/W
Selects hold outputs vs. set transfer value
during timers on time
Setup/Relay 1/Timer
Duration Time
40086
Unsigned
Integer
1
R/W
Sets the timer on duration time (sec)
Setup/Relay 1/Timer
Period Time
40087
Unsigned
Integer
1
R/W
Sets the period between timer on events
(mins)
Setup/Relay 1/Timer
Off Delay
40088
Unsigned
Integer
1
R/W
Sets the time the affected Sensor outputs
are held/transferred after the timer turns
off (sec)
Setup/Relay 1/Status
Level
40089
Unsigned
Integer
1
R/W
Sets the status level which will trigger the
relay
Setup/Relay 2
Source
40090
Unsigned
Integer
1
R/W
Selects data source for this relay
(0 = None; 1 = Real Time Clock;
2 = Sensor; 4 = Calculation)
Setup/Relay 2
Sensor Select
40091
Unsigned
Integer
1
R/W
Selects Sensor source when Source
= Sensor (0 = Sensor1; 1 = Sensor2)
Setup/Relay 2
Measurement
Select
40092
Unsigned
Integer
1
R/W
Selects measurement on the Sensor
(0 = Meas1 .. 3 = Meas4)
Table A-8 Controller ModBUS Registers (continued)
Group Name
Tag Name
Register #
Data Type
Length
R/W
Description