![Hach LANGE ULTRATURB sc Скачать руководство пользователя страница 47](http://html1.mh-extra.com/html/hach/lange-ultraturb-sc/lange-ultraturb-sc_operating-instructions-manual_3171606047.webp)
42
Operation
5.9 Data logger options
The data logger in the sc100 controller has three data archives (one for each
sensor and one for the value calculated) and three event archives (one for each
sensor and one for the controller).
While measured data is saved in the data archives at stipulated intervals, the
event archives collect numerous events such as configuration changes, alarms
and warning conditions.
The data is stored in data archives in a compressed binary format, in the event
archives in CSV format (comma separated values).
The archives can be downloaded either using the digital network port or via the
infrared interface using a special data transfer program (available from the
manufacturer).
OFF DELAY
Time delay (0-300 seconds) before the relay is normally switched off.
ON DELAY
Time delay (0-300 seconds) before the relay is normally switched on.
AS TIMER
PHASE
With the setting ”HIGH” the relay reacts to increasing measured values;
conversely, with ”LOW” the relay reacts to falling measured values.
SET SETPOINT
The measured value at which the relay is operated.
DEADBAND
The range within which the relay remains operated after the measured
value
Has dropped below the setpoint (for PHASE: HIGH)
Has increased beyond the setpoint (for PHASE: LOW).
OnMax TIMER
Time (0-999.9 min) that the relay remains switched on as a maximum.
OffMax TIMER
Time (0-999.9 min) that the relay remains switched off as a maximum.
OnMin TIMER
Time (0-999.9 min) that the relay remains switched on as a minimum.
OffMin TIMER
Time (0-999.9 min) that the relay remains switched off as a minimum.
AS WARNING
WARNING LEVEL
Warning level allocation from 0-32 for the warning.
Select
Menu level
Accept
1.
MAIN MENU
2.
SYSTEM SETUP
3.
LOG SETUP
4.
LOG CHANNEL 1 or 2
5.
TURBIDITY
6.
SET MODE or INTERVAL
7.
MAIN MENU or
Indication of measurement