1 7 7
Settings
96-8000 rev R June 2007
12 Parity Select
This setting defines parity for the first serial port (RS-232). When set to None, no parity bit is added to the serial
data. When set to Zero, a 0 bit is added. Even and Odd work like normal parity functions. Make sure you know what
your system needs, for example, XMODEM must use 8 data bits and no parity (set to “None”). This setting must
match the transfer rate from the personal computer.
13 Stop Bit
This setting designates the number of stop bits for the first serial port (RS-232). It can be 1 or 2. This setting must
match the transfer rate from the personal computer.
14 Synchronization
This changes the synchronization protocol between sender and receiver for the first serial port (RS-232). This setting
must match the transfer rate from the personal computer.
When set to RTS/CTS, the signal wires in the serial data cable are used to tell the sender to temporarily stop
sending data while the receiver catches up.
When set to XON/XOFF, the most common setting, ASCII character codes are used by the receiver to tell the
sender to temporarily stop.
The selection DC CODES is like XON/XOFF, except that paper tape punch or reader start/stop codes are sent.
XMODEM is a receiver-driven communications protocol that sends data in blocks of 128 bytes. XMODEM has added
reliability as each block is checked for integrity. XMODEM must use 8 data bits and no parity.
15 H & T Code Agreement
Turning this setting ON has the machine check to ensure that the H offset code matches the tool in the spindle. This
check can help to prevent crashes.
Settings 16-21
These settings can be turned on in order to stop unfamiliar operators from altering the machine s functions and
causing damage to the machine or workpiece.
16 Dry Run Lock Out
The Dry Run feature will not be available when this setting is turned ON.
17 Opt Stop Lock Out
The Optional Stop feature will not be available when this setting is on.
18 Block Delete Lock Out
The Block Delete feature will not be available when this setting is ON.
19 Feedrate Override Lock
The feedrate override buttons will be disabled when this setting is turned ON.
20 Spindle Override Lock
The spindle speed override buttons will be disabled when this setting is turned ON.
21 Rapid Override Lock
The axis rapid override buttons are disabled when this setting is turned ON.
22 Can Cycle Delta Z
This setting specifies the distance the Z-axis is retracted to clear chips during a G73 canned cycle. The range is 0.0
to 29.9999 inches (0-760 mm).
23 9xxx Progs Edit Lock
Turning this setting on will stop the 9000 series of programs from being viewed, edited or deleted. 9000 series
programs cannot be uploaded or downloaded with this setting on. Note: 9000 series programs are usually macro
programs.
Содержание Mill
Страница 12: ...96 8000 rev R June 2007 Safety 5 ...
Страница 14: ...96 8000 rev R June 2007 Safety 7 LATHE WARNING DECALS ...
Страница 15: ...8 Safety 96 8000 rev R June 2007 ...
Страница 17: ...10 Introduction 96 8000 rev R June 2007 ...
Страница 117: ...110 4 5 Axis Programming 96 8000 rev R June 2007 ...
Страница 199: ...Settings 192 96 8000 rev R June 2007 ...
Страница 213: ...206 Maintenance 96 8000 rev R June 2007 ...