2 0 2
Maintenance
96-8000 rev R June 2007
EC-1600
AND
HS 3/4/6/7 T
RANSMISSION
O
IL
Oil Fill
Oil
Drain
Oil Level View
Oil Fill Port
Oil Drain
Plug
Oil Sight
Glass
EC-1600
HS-3/4/6/7
Oil Check
Remove the sheet metal necessary to gain access to the transmission. View the sight glass on the side of the
transmission box as shown. The oil level should be half way on the sight glass. Fill as needed.
Oil Change
1.
Remove the sheet metal from the spindle head.
2.
Remove the drain plug as shown. Inspect the magnetic drainplug for signs of metal particles.
3.
Blow downward with an air hose in the vicinity of the fill hole to prevent dirt and metal particles from
entering the gear case. Remove the fill plug.
4.
Add Mobil DTE-25 gear oil until the oil level is half way up the sightglass.
5.
Run a spindle warm-up and check for leaks.
EC-S
ERIES
P
ALLET
C
HANGER
R
OTARY
T
ABLE
Oil Replacement
EC-300
Periodically check the oil level in the reservoir and keep it filled. It is not necessary to replace the oil.
Remove (8)
BHCS on
Bottom
Remove
(3) BHCS
on Sides
Clam
Shell
Rotary Table Oil Reservoir
Remove row
of (6) BHCS
on Top
EC-400 Full Fourth Axis Rotary Table (Perform Every 2 years)
Содержание Mill
Страница 12: ...96 8000 rev R June 2007 Safety 5 ...
Страница 14: ...96 8000 rev R June 2007 Safety 7 LATHE WARNING DECALS ...
Страница 15: ...8 Safety 96 8000 rev R June 2007 ...
Страница 17: ...10 Introduction 96 8000 rev R June 2007 ...
Страница 117: ...110 4 5 Axis Programming 96 8000 rev R June 2007 ...
Страница 199: ...Settings 192 96 8000 rev R June 2007 ...
Страница 213: ...206 Maintenance 96 8000 rev R June 2007 ...