H3C SR6608/6604 Routers Installation Manual
Chapter 1 Router Overview
1-9
Table 1-5
Description of the CF LED
LED
Status
Meaning
Off
No CF card is present or the CF card is not
recognizable.
On
A CF card is in position and has been detected.
CF (green)
Blinking
The system is accessing the CF card. In this state,
do not remove the CF card.
Note:
Do not remove the CF card when the CF LED is blinking. Otherwise, the file system on
the CF card will be damaged.
1.3.2 FIP-100
I. Introduction
Flexible interface platform-100 (FIP-100) is a type of line processing unit (LPU) that
supports H3C legacy multifunctional interface modules (MIMs). FIP-100 can be
inserted in slot 2, 3, 4, or 5 of the SR6608 or slot 2 or 3 of the SR6604. FIP-100 provides
two GigabitEthernet (GE) Combo interfaces and supports four MIMs at the same time.
FIP-100 is hot-swappable.
Note:
FIP-100 and FIP-200 are called LPUs in general.
“Hot-swapping” a module refers to first using the
remove
slot
slot-number
[
subslot
subslot-number
] command to stop the module and then pulling it out manually, or
inserting the module into its slot without powering off the device. For details about
the
remove slot
command, refer to
H3C SR66 Series Routers User Manual
.