1-12
Outputting System Information to the SNMP Module
The SNMP module receives the trap information only, and discards the log and debugging information
even if you have configured to output them to the SNMP module.
To monitor the device running status, trap information is usually sent to the SNMP network management
station (NMS). In this case, you need to configure to send traps to the SNMP module, and then set the
trap sending parameters for the SNMP module to further process traps. For details, refer to
SNMP
Configuration
.
Follow these steps to configure to output system information to the SNMP module:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enable information center
info-center enable
Optional
Enabled by default
Name the channel with a
specified channel number
info-center channel
channel-number name
channel-name
Optional
Refer to
Table 1-2
for default
channel names.
Configure the channel through
which system information can
be output to the SNMP module
info-center snmp channel
{
channel
-
number |
channel
-
name
}
Optional
By default, system information
is output to the SNMP module
through channel 5 (known as
snmpagent).
Configure the output rules of
the system information
info-center source
{
module
-
name
|
default
}
channel
{
channel
-
number |
channel
-
name
} [
debug
{
level
severity
|
state
state
} * |
log
{
level
severity
|
state
state
} * |
trap
{
level
severity
|
state
state
} * ] *
Optional
Refer to
Default Output Rules
of System
.
Configure the format of the
timestamp
info-center timestamp
{
debugging
|
log
|
trap
}
{
boot
|
date
|
none
}
Optional
The time stamp format for log,
trap and debugging information
is
date
by default.
Outputting System Information to the Web Interface
Support for this feature depends on the device model.
Содержание S5120-SI Series
Страница 61: ...7 8 Sysname ip http acl 2030...
Страница 138: ...2 10 PORT VLAN MODE GigabitEthernet1 0 1 2 MANUAL...
Страница 186: ...1 46 Instance Vlans Mapped 0 1 to 9 11 to 19 21 to 29 31 to 4094 1 10 2 20 3 30...
Страница 218: ...ii Displaying and Maintaining BOOTP Client Configuration 4 2 BOOTP Client Configuration Example 4 3...
Страница 255: ...1 12...
Страница 381: ...ii Troubleshooting RADIUS 1 32...
Страница 577: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...