![H3C S5120-SI Series Скачать руководство пользователя страница 624](http://html2.mh-extra.com/html/h3c/s5120-si-series/s5120-si-series_operation-manual_3711174624.webp)
1-4
Information
channel
number
Default
channel name
Default output destination
Description
debugging information.
9 channel9
Not
specified
Receives log, trap, and
debugging information.
Configurations for the seven output destinations function independently and take effect only after the
information center is enabled.
Outputting System Information by Source Module
The system is composed of a variety of protocol modules, board drivers, and configuration modules.
The system information can be classified, filtered, and output according to source modules. You can
use the
info-center source ?
command to view the supported information source modules.
Default Output Rules of System Information
The default output rules define the source modules allowed to output information on each output
destination, the output information type, and the output information level as shown in
Table 1-3
, which
indicates that by default and in terms of all modules:
z
All log information is allowed to be output to the Web interface; log information with severity level
equal to or higher than informational is allowed to be output to the log host; log information with
severity level equal to or higher than warning is allowed to be output to the console, monitor
terminal, and log buffer; log information is not allowed to be output to the trap buffer and the SNMP
module.
z
All trap information is allowed to be output to the console, monitor terminal, Web interface, and log
file; trap information with severity level equal to or higher than warning is allowed to be output to the
trap buffer and SNMP module; trap information is not allowed to be output to the log buffer.
z
All debugging information is allowed to be output to the console and monitor terminal; debugging
information is not allowed to be output to the log host, trap buffer, log buffer, the SNMP module and
Web interface,.
Table 1-3
Default output rules for different output destinations
LOG
TRAP
DEBUG
Output
destinati
on
Modules
allowed
Enabled/
disabled
Severity
Enabled/
disabled
Severity
Enabled/
disabled
Severity
Console
default
(all
modules)
Enabled Warning Enabled Debug Enabled Debug
Monitor
terminal
default
(all
modules)
Enabled Warning Enabled Debug Enabled Debug
Содержание S5120-SI Series
Страница 61: ...7 8 Sysname ip http acl 2030...
Страница 138: ...2 10 PORT VLAN MODE GigabitEthernet1 0 1 2 MANUAL...
Страница 186: ...1 46 Instance Vlans Mapped 0 1 to 9 11 to 19 21 to 29 31 to 4094 1 10 2 20 3 30...
Страница 218: ...ii Displaying and Maintaining BOOTP Client Configuration 4 2 BOOTP Client Configuration Example 4 3...
Страница 255: ...1 12...
Страница 381: ...ii Troubleshooting RADIUS 1 32...
Страница 577: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...