![H3C S5120-SI Series Скачать руководство пользователя страница 601](http://html2.mh-extra.com/html/h3c/s5120-si-series/s5120-si-series_operation-manual_3711174601.webp)
1-5
Configuration
System clock displayed by
the display clock command
Example
If
date-time
is in the daylight
saving time range, “
date-time”
+ “
summer-offset”
is displayed.
Configure: clock datetime 8:00
2007/1/1 and clock
summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 10:00:00 ss Mon
01/01/2007
If
date-time
is not in the daylight
saving time range,
date-time
is
displayed.
Configure: clock summer-time
ss one-off 1:00 2007/1/1 1:00
2007/8/8 2 and clock datetime
1:00 2008/1/1
Display: 01:00:00 UTC Tue
01/01/2008
Configure: clock summer-time
ss one-off 1:00 2007/1/1 1:00
2007/8/8 2 and clock datetime
1:30 2007/1/1
Display: 23:30:00 UTC Sun
12/31/2006
[1], 3 and 1
date-time
is in the daylight
saving time range:
If the value of
“date-time” -
“summer-offset”
is not in the
summer-time range,
“date-time” - “summer-offset”
is
displayed;
If the value of
“date-time” -
“summer-offset”
is in the
summer-time range,
date-time
is displayed.
Configure: clock summer-time
ss one-off 1:00 2007/1/1 1:00
2007/8/8 2 and clock datetime
3:00 2007/1/1
Display: 03:00:00 ss Mon
01/01/2007
Configure: clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 02:00:00 zone-time
Sat 01/01/2005
If the value of the original
system clock ± “zone-offset” is
not in the summer-time range,
the original system clock ±
“zone-offset” is displayed.
Configure: clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2005/1/1 1:00 2005/8/8 2
Display: 04:00:00 ss Sat
01/01/2005
2 and 3 or 3 and 2
If the value of the original
system clock ± “zone-offset” is
in the summer-time range, the
original system clock ±
“zone-offset” + ”summer-offset”
is displayed.
Configure: clock datetime 1:00
2007/1/1, clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2008/1/1 1:00 2008/8/8 2
Display: 02:00:00 zone-time
Mon 01/01/2007
1, 2 and 3 or 1, 3 and 2
If the value of
"
date-time
"±"
zone-offset
" is not
in the summer-time range,
"date-time"±"zone-offset" is
displayed.
Configure: clock datetime 1:00
2007/1/1, clock timezone
zone-time add 1 and clock
summer-time ss one-off 1:00
2007/1/1 1:00 2007/8/8 2
Display: 04:00:00 ss Mon
01/01/2007
Содержание S5120-SI Series
Страница 61: ...7 8 Sysname ip http acl 2030...
Страница 138: ...2 10 PORT VLAN MODE GigabitEthernet1 0 1 2 MANUAL...
Страница 186: ...1 46 Instance Vlans Mapped 0 1 to 9 11 to 19 21 to 29 31 to 4094 1 10 2 20 3 30...
Страница 218: ...ii Displaying and Maintaining BOOTP Client Configuration 4 2 BOOTP Client Configuration Example 4 3...
Страница 255: ...1 12...
Страница 381: ...ii Troubleshooting RADIUS 1 32...
Страница 577: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...