![H3C S5120-SI Series Скачать руководство пользователя страница 563](http://html2.mh-extra.com/html/h3c/s5120-si-series/s5120-si-series_operation-manual_3711174563.webp)
1-5
z
The
entry-number
must be globally unique and cannot be used on another interface; otherwise, the
operation fails.
z
You can configure multiple history entries on one interface, but the values of the
entry
-
number
arguments must be different, and the values of the
sampling
-
interval
arguments must be different
too; otherwise, the operation fails.
z
You can create up to 100 history entries for the device.
z
When you create an entry in the history table, if the specified
buckets number
argument exceeds
the history table size supported by the device, the entry will be created. However, the validated
value of the
buckets
number
argument corresponding to the entry is the history table size
supported by the device.
Configuring the RMON Alarm Function
Configuration Prerequisites
z
If you need to configure that the managed devices send traps to the NMS when it triggers an alarm
event, you should configure the SNMP agent as described in
SNMP Configuration
before
configuring the RMON alarm function.
z
If the alarm variable is the MIB variable defined in the history group or the Ethernet statistics group,
you must make sure that the RMON Ethernet statistics function or the RMON history statistics
function is configured on the monitored Ethernet interface; otherwise, the creation of the alarm
entry fails, and no alarm event is triggered.
Configuration Procedure
Follow these steps to configure the RMON alarm function:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Create an event entry in the event
table
rmon event entry
-
number
[
description
string
] {
log
|
log-trap log
-
trapcommunity |
none
|
trap trap
-
community
} [
owner
text
]
Required
Create an entry in the alarm table
rmon alarm
entry
-
number alarm
-
variable
sampling
-
interval
{
absolute
|
delta
}
rising-threshold
threshold
-
value1
event
-
entry1
falling-threshold
threshold
-
value2
event
-
entry2
[
owner
text
]
Create an entry in the private
alarm table
rmon prialarm entry-number
prialarm-formula prialarm-des
sampling-interval
{
absolute
|
changeratio
|
delta
}
rising-threshold threshold-value1
event-entry1 falling-threshold
threshold-value2 event-entry2 entrytype
{
forever
|
cycle cycle-period
} [
owner
text
]
Required
Use at least one
command.
Содержание S5120-SI Series
Страница 61: ...7 8 Sysname ip http acl 2030...
Страница 138: ...2 10 PORT VLAN MODE GigabitEthernet1 0 1 2 MANUAL...
Страница 186: ...1 46 Instance Vlans Mapped 0 1 to 9 11 to 19 21 to 29 31 to 4094 1 10 2 20 3 30...
Страница 218: ...ii Displaying and Maintaining BOOTP Client Configuration 4 2 BOOTP Client Configuration Example 4 3...
Страница 255: ...1 12...
Страница 381: ...ii Troubleshooting RADIUS 1 32...
Страница 577: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...