![H3C S5120-SI Series Скачать руководство пользователя страница 395](http://html2.mh-extra.com/html/h3c/s5120-si-series/s5120-si-series_operation-manual_3711174395.webp)
1-14
AAA supports the following accounting methods:
z
No accounting: The system does not perform accounting for the users.
z
Local accounting: Local accounting is implemented on the access device. It is for collecting
statistics on the number of users and controlling the number of local user connections; it does not
provide statistics for user charge.
z
Remote accounting: The access device cooperates with a RADIUS server for accounting of users.
You can configure local accounting as the backup method to be used when the remote server is not
available.
By default, an ISP domain uses the local accounting method.
Before configuring accounting methods, complete these three tasks:
1) For RADIUS accounting, configure the RADIUS scheme to be referenced first. The local and none
authentication methods do not require any scheme.
2) Determine the access mode or service type to be configured. With AAA, you can configure an
accounting method specifically for each access mode and service type, limiting the accounting
protocols that can be used for access.
3) Determine whether to configure an accounting method for all access modes or service types.
Follow these steps to configure AAA accounting methods for an ISP domain:
To do…
Use the command…
Remarks
Enter system view
system-view
—
Enter ISP domain view
domain
isp-name
—
Enable the accounting optional
feature
accounting optional
Optional
Disabled by default
Specify the default accounting
method for all types of users
accounting default
{
local
|
none
|
radius-scheme
radius-scheme-name
[
local
] }
Optional
local
by default
Specify the accounting method
for LAN users
accounting lan-access
{
local
|
none
|
radius-scheme
radius-scheme-name
[
local
] }
Optional
The default accounting method
is used by default.
Specify the accounting method
for login users
accounting login
{
local
|
none
|
radius-scheme
radius-scheme-name
[
local
] }
Optional
The default accounting method
is used by default.
Содержание S5120-SI Series
Страница 61: ...7 8 Sysname ip http acl 2030...
Страница 138: ...2 10 PORT VLAN MODE GigabitEthernet1 0 1 2 MANUAL...
Страница 186: ...1 46 Instance Vlans Mapped 0 1 to 9 11 to 19 21 to 29 31 to 4094 1 10 2 20 3 30...
Страница 218: ...ii Displaying and Maintaining BOOTP Client Configuration 4 2 BOOTP Client Configuration Example 4 3...
Страница 255: ...1 12...
Страница 381: ...ii Troubleshooting RADIUS 1 32...
Страница 577: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...