![H3C S5120-SI Series Скачать руководство пользователя страница 555](http://html2.mh-extra.com/html/h3c/s5120-si-series/s5120-si-series_operation-manual_3711174555.webp)
1-11
The configurations on the agent and the NMS must match.
3) Verify the configuration
z
After the above configuration, an SNMP connection is established between the NMS and the agent.
The NMS can get and configure the values of some parameters on the agent through MIB nodes.
z
Execute the
shutdown
or
undo shutdown
command to an idle interface on the agent, and the
NMS receives the corresponding trap.
SNMP Logging Configuration Example
Network requirements
z
As shown in
Figure 1-5
, the NMS and the agent are connected through an Ethernet.
z
The IP address of the NMS is 1.1.1.2/24
z
The IP address of the agent is 1.1.1.1/24
z
Configure SNMP logging on the agent to record the operations performed by the NMS to the agent
Figure 1-5
Network diagram for SNMP logging
Configuration procedure
For the configurations for the NMS and agent, refer to
SNMPv1/SNMPv2c Configuration Example
and
SNMPv3 Configuration Example
.
# Enable logging display on the terminal. (This function is enabled by default, so that you can omit this
configuration).
<Sysname> terminal monitor
<Sysname> terminal logging
# Enable the information center to output the system information with the severity level equal to or
higher than
informational
to the console port.
Содержание S5120-SI Series
Страница 61: ...7 8 Sysname ip http acl 2030...
Страница 138: ...2 10 PORT VLAN MODE GigabitEthernet1 0 1 2 MANUAL...
Страница 186: ...1 46 Instance Vlans Mapped 0 1 to 9 11 to 19 21 to 29 31 to 4094 1 10 2 20 3 30...
Страница 218: ...ii Displaying and Maintaining BOOTP Client Configuration 4 2 BOOTP Client Configuration Example 4 3...
Страница 255: ...1 12...
Страница 381: ...ii Troubleshooting RADIUS 1 32...
Страница 577: ...1 8 Return to the upper directory Sysname cd Display the current working directory Sysname pwd flash...