28
ADICOS HOTSPOT-1000
410-2410-001 EN12
TECHNICAL DATA
10 Technical Data
Power supply
21,6 – 40 V DC (A fault indication is trig-
gered when voltage falls below 20 V)
Power consumption (with-
out heater / with heater)
2 VA / 10 VA. Power consumption
is briefly higher upon startup
Device temperature range
-10 – 50 °C. Failure is triggered below the
default temperature limit (standard: -15 °C)
Relative humidity:
< 95 % relative humidity
•
Non-condensing
•
With continuous condensation, when op-
tional detector heater is built in
Purge Air Adapter
4 mm quick connector for hose connection
Enclosure
Coated die cast aluminum
Dimensions (H x W x L)
90 x 100 x 100 mm (not includ-
ing dust/splash guard)
Weight
0.84 kg
Degree of protection
IP 64
Mounting
Overhead / diagonally / on the ball joint
Electrical connection
ADICOS connection cable
(12-lead) with bayonet lock
Service bus
M-Bus: 4800 baud
Startup time (ready for operation)
After about 10 seconds
Resolution
32 x 31 pixels
Capture angle
53° x 52°
Reaction time
< 1 second
Temporal resolution
0.1 second or 1 second
(depending on configuration)
Содержание ADICOS HOTSPOT-1000
Страница 36: ......