INSTALLATION
11
ADICOS HOTSPOT-1000
410-2410-001 EN12
Electromagnetic radiation
The electronics contained in the ADICOS HOTSPOT-1000 can be impaired by electromag netic
radiation. So do not place the detector near high voltage equipment. Always use shielded ca-
ble.
5.1.2
Requirements of Proper Detection
To ensure reliable and correct operation of the ADICOS HOTSPOT-1000 as well as proper de-
tection, always consider the following factors when choosing a place to attach the device.
Visibility
The ADICOS HOTSPOT-1000 must always have a clear, unobstructed view of the installation
to be monitored. If the object to be monitored is obscured or is not within the visibility range
of the ADICOS HOTSPOT-1000, the device will not be able to detect any heat sources and
trigger an alarm.
Distance and detection area
The detection area is determined by the distance between the detector and the object to be
monitored. So the distance or the installation location should be selected such that the object
to be monitored can be covered completely by the detector’s field of view. This ensures max-
imum sensitivity.
Rule of thumb: Detection area when positioned vertically: tan(26.5) x 2 x height
Example:
An 80 cm wide conveyor belt is to be monitored to detect any moving hot spots. So the
HOTSPOT detector should be installed about 80 - 100 mm above the transport belt.
Distance [m]
Object resolution [cm]
Width of detection area [m]
1
3
1
3
10
3
5
16
5
10
32
10
15
48
15