![Grundig GHP-MM08 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/grundig/ghp-mm08/ghp-mm08_service-manual_2273072058.webp)
58 / EN
Heat Pump Monobloc Inverter / User Manual
202202
Heat Pump Space Heater 56
4.4.14 P25 diagnosis and analysis
4.4.14.1 Diagnosis
Code P25 indicates outlet water pressure sensor had an error. If there are no other errors
except for the water pressure sensor error, Heat pump will continue to operate.
4.4.14.2 Possible causes
!
Outlet water pressure sensor is not connected properly
!
Outlet water pressure sensor has malfunctioned.
4.4.14.3 Analysis and action
Outlet water pressure sensor connection on
Hydraulic module PCB is loose?
P25
Yes
Ensure the sensors is connected
properly
NO
Water pressure sensor has short-circuit or
malfunctioned?
Yes
Replace the sensor
NO
Replace hydraulic module PCB
Water pressure sensor is plugged into the
wrong port on Hydraulic module?
Yes
Ensure the sensors is connected
properly
NO