23 / EN
Heat Pump Monobloc Inverter / User Manual
21 Heat Pump Space Heater 202202
59
DC fan resonance point 2
SR2
0/15
rpm
0
~
1000/15
1
60
DC fan resonance point 3
SR3
0/15
rpm
0
~
1000/15
1
61
Test mode PWM pump speed
Test_P
100
%
50
~
100
1
62
PWM pump minimum speed Min-PWMout
70
%
50
~
100
1
63
Trv is effective or not
enTrV
1
0/1
0-disable
1-enable
1
64
Four way switching fault
judgment temperature
difference
Trv
3
℃
0
~
10
1
65
EVI heat or DHW superheat
SHe
6
℃
-5
~
25
1
66
Cool test mode EEV-2 open
EEV_C
0/5
P
(0
~
480)/5
1
67
Heat test mode EEV-2 open
EEV_H
150/5
P
(0
~
480)/5
1
68
DHW test mode EEV-2 open
EEV_W
150/5
P
(0
~
480)/5
1
69
Commercial mode heating
frequency
FreqTestH
60
Hz
20
~
100
1
70
Commercial mode heating
EEV-1 open
EEVTestH-1
250/5
P
(0
~
480)/5
1
71
Commercial mode heating
EEV-2 open
EEVTestH-2
150/5
P
(0
~
480)/5
1
72
Commercial mode cooling
frequency
FreqTestC
40
Hz
20
~
100
1
73
Commercial modecooling EEV-1
open
EEVTestC-1
300/5
P
(0
~
480)/5
1
74
Commercial mode cooling
EEV-2 open
EEVTestC-2
0
P
(0
~
480)/5
1
75
Chassis heater on time
BaseHeatTime
6
10Min
0
~
100
1
76
Group control address
IP
0
0-15
1
77
Low pressure check type
LPS
1
/
0-low pressure
switch
1- low
pressure
sensor
1
78
Pump running status in cooling
standby mode
C-Pump
3
0/1
0-on 1min off
3min
1-on 1min off
1
Содержание GHP-MM08
Страница 27: ...27 EN Heat Pump Monobloc Inverter User Manual...
Страница 28: ...28 EN Heat Pump Monobloc Inverter User Manual 3 9 2 GHP MM14 GHP MM16...
Страница 29: ...29 EN Heat Pump Monobloc Inverter User Manual...
Страница 72: ...72 EN Heat Pump Monobloc Inverter User Manual Figure 4 19 9 14 16kw...
Страница 83: ...Beko Grundig Deutschland GmbH Rahmannstra e 3 65760 Eschborn www grundig com...