background image

Un

ité

 d

e c

lim

ati

sat

io

n m

ura

le

bib

lo

c

MA

NU

EL 

DU

 P

RO

PR

TA

IR

E

Veu

ille

z li

re 

atte

ntiv

em

ent

 ce

 m

anu

el d

u p

rop

rié

tai

re 

ava

nt d

e fa

ire

 fo

nct

ion

ner

 ce

t a

ppa

rei

et c

ons

erv

ez-

le 

à d

es 

fin

s d

e ré

fér

enc

e.

006

30-

19/

04/

12

© T

ous

 dr

oits

 ré

ser

vés

, S

unr

ise

 Tr

ade

x C

orp

., 2

012

MO

DÈL

ES 

GW

H09

UB-

D3D

NA3

A/I

GW

H09

UB-

D3D

NA2

A/I

GW

H09

UB-

D3D

NA1

A/I

GW

H12

UB-

D3D

NA3

A/I

GW

H12

UB-

D3D

NA1

A/I

GW

H12

UB-

D3D

NA2

A/I

GW

H18

UC-

D3D

NA1

A/I

GW

H18

UC-

D3D

NA2

A/I

WW

W.G

REE

.C

A

St-

Mat

hie

u-d

e-B

elo

eil 

(Q

uéb

ec)

 C

an

ad

a

1-8

66-

680

-G

REE

Split Air Conditioner Wall

Mounted Model

OWNER’S MANUAL

Please read this owner's manual carefully before operating,

and keep it for reference.

00630-19/04/12

© Copyright, Sunrise Tradex Corp., 2012

MODELS

GWH09UB-D3DNA3A/I

GWH09UB-D3DNA2A/I

GWH09UB-D3DNA1A/I

GWH12UB-D3DNA3A/I

GWH12UB-D3DNA1A/I

GWH12UB-D3DNA2A/I

GWH18UC-D3DNA1A/I

GWH18UC-D3DNA2A/I

WWW.GREE.CA

St-Mathieu-de-Beloeil (Québec) Canada

1-866-680-GREE

00630_U-COO

L_ G

WH09UB-D3DNA/

1_(12), (18)_Mise 

en page 

1  12-05-17 

 15:

01  Page1

Содержание GWH09UB-D3DNA1A/I

Страница 1: ...re operating and keep it for reference 00630 19 04 12 Copyright Sunrise Tradex Corp 2012 MODELS GWH09UB D3DNA3A I GWH09UB D3DNA2A I GWH09UB D3DNA1A I GWH12UB D3DNA3A I GWH12UB D3DNA1A I GWH12UB D3DNA2...

Страница 2: ...e refer to the actual objects for reference This appliance is not intended for use by people including children with reduced physical sensory or mental capabilities or lack of experience and knowledge...

Страница 3: ...er Horizontal louver Wall pipe Binding tape Connection wires Drain hose Indoor unit Cool Dry Heat Set temp Power The icons displayed Remote controller 1 Parts and their functions INDOOR UNIT 1 1 OPERA...

Страница 4: ...g 4 MODE Press to select the running mode AUTO COOL DRY FAN HEAT 5 FAN Press to set the fan speed 6 SWING Press to set the swing angle of the louvers 7 I FEEL 8 Press to set the OUTSIDE or RECYCLED AI...

Страница 5: ...dels with the heating function AUTO is the default mode when the unit is started When in AUTO mode the set temperature will not be displayed on the unit s LED screen and the unit will automatically se...

Страница 6: ...anging the temperatures by simply pressing the Turbo button to confirm the temperature and go to the next one Note When setting or verifying the temperature curve if no button is pressed within 10 sec...

Страница 7: ...cted temperature of 8 C 46 F if Fahrenheit is chosen Repeat the operation to cancel the function 21 About the back lighting function When first turned on the unit lights turn on for four seconds They...

Страница 8: ...Dip a piece of cloth into the water colder than 45 and dry it Then wipe the dirty part of front panel Disconnect the power supply before cleaning and maintenance Do not splash water on the units for...

Страница 9: ...e the auto defrosting function will act the heat running will stop for 8 10mins During the auto defrosting the fan motors of indoor unit and outdoor unit will stop During the defrosting the indoor ind...

Страница 10: ...nning the unit to prevent leakage of cool air and to save energy Close curtains or glass windows when cooling to prevent heat from sunlight which may increase electricity costs In case of ineffective...

Страница 11: ...may cause damage or personal injury Also pay close attention when children are nearby Do not allow the air to flow directly at people especially infants the elderly or the sick Do not place a heater o...

Страница 12: ...ith the decrease of room temperature and humidity Cracking noise This is the sound of friction caused by expansion and or contraction of panel or other parts due to the change of temperature C5 Malfun...

Страница 13: ...by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Installation Site Instructions Proper installation site is vital for correct a...

Страница 14: ...Space to the ceiling Space to the wall 15 cm above 15cm away 15cm above 3 0 0 c m a b o v e 250 cm above Space to the floor Air outlet Space to the wall The dimensions of the space necessary for prope...

Страница 15: ...let for smooth drainage of condensate 2 Fix the mounting plate on the wall with screws 3 Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg Meanwhile the weight shou...

Страница 16: ...not damage the connection pipe Ensure that the joint nut is tightened firmly otherwise it may cause leakage NOTE All wires between indoor and outdoor units must be connected by the qualified electric...

Страница 17: ...d voltage on the nameplate It may cause electric malfunction or damage the part Is the electrical wiring and piping connection installed correctly and securely It may cause electric malfunction or dam...

Страница 18: ...r s manual 3 Damage to the finish of the unit enclosure or to other outer features caused by wear 4 Filter 5 Damage caused by repairs or modifications to the air conditioner made by any person not dul...

Отзывы: