FC9000-UM-251-9370 38
9 TROUBLESHOOTING
9.7.5
Self Diagnostic Test
Operation status can be tested by self diagnostic test by operating the sensors and switches following the
instruction on the screen.
Operation
(1)
Confirm that the power is turned off.
(2) Turn the power on without loading the media.
(3) Press the PAUSE/MENU key to display the menu below.
(4) Press the Left position (
t
) key (TEST) to display the menu below.
(5) Press the down position (
q
) key (TEST) to display the menu below.
(6) Press the F1 key (DIAGNOSTICS) to display the menu below.
(7) Press the F1 key (DONE).
The first testing menu is displayed. And follow the instructions on the menu.
(8)
Press the F1 key to continue to the next test, after you check the CAM lever sensor.