FC9000-UM-251-9370 8-6
8 Electrical Adjustment
8.3 DIP Switch Settings
The location of DIP switch on the main board
Factory presets (Normal Mode)
This setting depends on the model.
Dip Switch (SW1)
1
2
3
4
5
6
7
8
Model
1 2 3 4 5 6 7 8
ON
OFF
OFF OFF OFF OFF OFF OFF OFF OFF FC9000-75
1 2 3 4 5 6 7 8
ON
OFF
OFF OFF OFF OFF OFF OFF ON OFF
FC9000-75
2nd pen option model
1 2 3 4 5 6 7 8
ON
OFF
ON OFF OFF OFF OFF OFF OFF OFF FC9000-100
1 2 3 4 5 6 7 8
ON
OFF
ON OFF OFF OFF OFF OFF ON OFF
FC9000-100
2nd pen option model
1 2 3 4 5 6 7 8
ON
OFF
OFF ON OFF OFF OFF OFF OFF OFF FC9000-140
1 2 3 4 5 6 7 8
ON
OFF
OFF ON OFF OFF OFF OFF ON OFF
FC9000-140
2nd pen option model
1 2 3 4 5 6 7 8
ON
OFF
ON ON OFF OFF OFF OFF OFF OFF FC9000-160
1 2 3 4 5 6 7 8
ON
OFF
ON ON OFF OFF OFF OFF ON OFF
FC9000-160
2nd pen option model
Note:
The NOV-RAM CLEAR must perform when the dip switch setting was changed from previous model setting.