Additional Repair and Replacement Instructions
30
332203F
First Time Hose Installation
1.
Be sure hose reel is secured to a flat surface or
installed in it’s service location. See Disassembly,
Step 8b, page 13.
2.
Verify the spring is not under tension. If there is
spring tension, follow Removing Spring Tension pro-
cedure provided on page 37.
3.
For easier hose installation, Graco recommends
removing the outlet (30) from the spool. To do this
remove bolts (37) holding outlet to the spool (F
IG
.
62).
4.
Apply pipe thread sealant or wrap PTFE tape
around the threads of reducer (53) (if needed). Then
install reducer (53) in the end of the outlet (F
IG
. 62).
Use two wrenches on the flats, working in opposite
directions, to securely tighten the reducer to the out-
let fitting.
NOTE:
A reducer (53) is not required for all installa-
tions. It is only necessary if the hose diameter is
smaller than the diameter of the outlet (30).
5.
Install ball stop to dispense end of hose.
To install the ball stop:
a.
Position each half of the stop (45) near the out-
let end of the hose (F
IG
. 52).
b.
Thread screws (46) through holes in stop pieces
(45).
c.
Tighten nuts (47)until the outside edges of the
stop contact each other.
6.
Uncoil and extend hose.
7.
Feed opposite end of the hose, through the rollers
(a), then under the reel (b), and around the back (c)
of the spool.
•
Never allow the reel to spin freely. Doing so
causes the spool to spin out of control, which
could cause serious injury if you are hit by the
hose.
• Always wear heavy, non-slippery gloves when
adjusting the spring tension to protect your hands
from being cut on the hose reel.
F
IG
. 62: Low Pressure Outlet shown. Medium
Pressure models use 6 bolts.
37
30
53
F
IG
. 63
F
IG
. 64
45
46
47
b
c
a