Additional Repair and Replacement Instructions
332203F
29
12. Verify outlet o-ring (34) is in place on outlet (30).
Apply a thin layer of grease (G) to o-ring as shown
in F
IG
. 60.
d.
Install outlet (30) to spool. Replace and tighten
all bolts (37) securely. Torque bolts to 24 to 30
ft. pounds (32.54 to 40.67 N.m) (F
IG
. 61).
NOTE:
• Low Pressure Models (shown in F
IG
. 51) use 4
bolts (37).
• Medium Pressure Models (not shown) use 6
bolts (37).
• Always use all bolts provided.
13. Uncoil and extend hose.
14. Remove c-clamp (A) (installed in Step 7, page 28).
15. Disengage latch by pulling on hose to release it.
16. Use your hand to guide the hose as it rewinds onto
the reel.
17. Adjust spring tension if needed. See Adjusting
Spring Tension, page 35.
18. Remove cap from end of hose and install dispense
valve to end of hose.
F
IG
. 60
F
IG
. 61: Low Pressure Model Shown
(G)
30
34
30
37
Always wear heavy, non-slippery gloves when adjust-
ing the spring tension to protect your hands from being
cut on the hose reel.