General Repair Information
10
332203F
General Repair
Information
•
Always use all the new parts included in repair kit.
Do not reuse old parts.
•
Unless otherwise indicated, reference numbers
used in the following instructions refer to
the Parts
Drawing on page 40 and the Parts List beginning on
page 40.
•
See Related Kits (page 43) or contact Graco Cus-
tomer Service to identify the kit needed for your
repair.
•
All instructions assume the hose reel has been
installed and is in service.
Bare Reels
Instructions for bare reels are included in the XD40 and
XD50 Hose Reels Installation and Operation instruction
manual provided with your hose reel and on Graco.com.
Pressure Relief Procedure
Follow the Pressure Relief Procedure whenever
you see this symbol.
1.
Turn off power supply to fluid pump.
2.
Isolate the supply pump fluid supply line.
3.
Open the dispensing valve until pressure is fully
relieved.
If you suspect the dispensing valve or extension is
clogged or that pressure has not been fully relieved after
following the steps above, VERY SLOWLY loosen
coupler or hose end coupling to relieve pressure
gradually, then loosen completely. Clear the obstruction.
Grounding
This equipment stays pressurized until pressure is
manually relieved. To help prevent serious injury from
pressurized fluid, such as skin injection, splashing
fluid and moving parts, follow the Pressure Relief
Procedure when you stop spraying and before
cleaning, checking, or servicing the equipment.
The equipment must be bonded (grounded) to the
truck. Grounding reduces the risk of static shock
due to static build up on the equipment. Refer to
your pump instruction manual for grounding
instructions.
F
IG
. 1