Installation
Installation
Installation
All electrical wiring must be done by a qualified
electrician and comply with all local codes and
regulations.
General
General
General Information
Information
Information
The Typical Installation shown in Fig.
Fig.
Fig. 1
1
1 is only a
guide for selecting and installing system components.
Reference letters in the text, for example (A), refer to
the callouts in the figures.
The SDU consists of parts which are stationary and
parts attached to the air cylinder center shafts. The
parts, such as the pump and ram plate, attached
to the air cylinder center shafts will raise and lower
(move) during normal operation. These moving parts
comprise the ram.
Performing different steps in the operation of the
SDU will require use of the controls located on the
control panel. Refer to the table under the illustration
that corresponds with the control panel installed
on the SDU for the use of those controls. Learn
what each control does before using the SDU in a
production situation.
Choosing
Choosing
Choosing a
a
a Location
Location
Location for
for
for the
the
the SDU
SDU
SDU
1.
Choose a location for the SDU so the air controls
are easily accessible. Ensure that there is
enough space overhead for the ram to rise fully
and the control box cover can be opened without
interference. See
.
2.
Make sure the surface is flat and that the SDU
doesn’t wobble.
NOTE:
NOTE:
NOTE: If the SDU is being located in a permanent
location, use the four holes in the baseplate as a
guide to locate where to drill holes for mounting
hardware.
3.
For ease of operation and service, locate the
SDU so the fluid outlet port is easily accessible.
Unpacking
Unpacking
Unpacking the
the
the SDU
SDU
SDU
Before unpacking, examine packing materials for
signs of damage. If damaged, take pictures of the
damage and contact Graco for directions on how to
proceed.
1.
Remove packing materials and mounting bolts
from the base.
2.
Attach a hoisting strap around the upper end of
each air cylinder, below the crossbar. Ensure
that air hoses or laser sensor are not damaged
by the straps.
3.
Use a forklift or overhead hoist to lift the SDU off
the shipping pallet.
NOTE:
NOTE:
NOTE: If using casters on a pneumatic unit,
attach at this time.
4.
Place the SDU at the desired location.
5.
Permanently mount the electro-pneumatic unit.
8
3A5402J