Electro-pneumatic Control Panel Display Screens
Icon
Icon
Icon /// Field
Field
Field
Description
Description
Description
AUTO
AUTO
AUTO SEQUENCE
SEQUENCE
SEQUENCE
Current
Current
Current Recipe
Recipe
Recipe
Name of the recipe selected for unloading this drum. Click in this field to display the
recipe selection screen.
Start
Start
Start
Begin drum unloading at the current state of the automatic sequence. If the sequence
was stopped before completing, the drum unloading resumes at the point where the
unloading was stopped.
Stop
Stop
Stop
Stop drum unloading. If the automatic sequence is not complete, the drum unloading
status is retained so that the sequence can be completed if started again.
Reset
Reset
Reset
Resets the automatic sequence state, deflates the seal, and if “Auto Raise” is selected
in the current recipe, will raise the ram.
Auto
Auto
Auto Sequence
Sequence
Sequence Enabled
Enabled
Enabled
Flashes in the upper-left corner of the screen next to the date and time once the
automatic sequence has been activated. Once the sequence is fully enabled, the icon
will also flash over the Start button.
NOTE:
NOTE:
NOTE: If the Start button is released too soon during the loading process, then the
sequence will stop. The icon will still flash next to the date and time to show that
loading started, but did not finish. To continue the automatic sequence, press and
hold the Start button until the icon flashes over the Start button.
Partial
Partial
Partial Drum
Drum
Drum
Available settings:
Partial drum
Not a partial drum
Batching
Batching
Batching
If checked, unload the batch size specified in the Batch Amount field. If unchecked,
unloading will not automatically stop until the drum has been emptied.
Ram position in the drum.
Note:
Note:
Note: The red line indicates the approximate ram plate position at which the Drum
Low status flag will be set.
STATUS
STATUS
STATUS MESSAGES
MESSAGES
MESSAGES
Available statuses:
Condition not met
Condition met
Seal
Seal
Seal Inflated
Inflated
Inflated
The ram plate seal is inflated.
System
System
System Loaded
Loaded
Loaded
The pump is primed and ready to evacuate the drum. This is based on the pump
primed timer.
Drum
Drum
Drum Low
Low
Low
Ram assembly has reached the Drum Low position.
Drum
Drum
Drum Empty
Empty
Empty
Ram assembly has reached the Drum Empty position.
Auto
Auto
Auto Sequence
Sequence
Sequence
Complete
Complete
Complete
The actions specified by the selected recipe have been completed. When this state is
achieved, all other status states are cleared.
Batching
Batching
Batching Sequence
Sequence
Sequence
Complete
Complete
Complete
Displays when Batching has been enabled. When lit, indicates that the dispensed
material value specified is achieved.