NOTICE
NOTICE
NOTICE
To prevent pinching or damaging the seal during
drum insertion, only inflate the seal when the top
lip of the ram plate is at, or below, the top edge
of the drum.
The drum stops are a cam which will allow adjustment
for different types of drums.
1.
Loosen the bolt in each drum stop (H) and rotate
them away from the ram plate.
2.
Raise the ram assembly.
3.
Place an empty drum on the SDU baseplate.
4.
Lower the ram assembly near the top of the drum.
5.
Position the drum to properly align with the ram
plate.
6.
Lower the ram assembly partially into the drum
and inflate the ram plate seal (if applicable).
7.
Rotate each drum stop to contact the drum and
tighten the drum stop bolts.
8.
Deflate the ram plate seal (if applicable), raise
the ram assembly, and remove the empty drum.
System
System
System Setup
Setup
Setup (Pneumatic
(Pneumatic
(Pneumatic Control)
Control)
Control)
1.
Connect supply air.
2.
Adjust air pressure settings for control functions.
3.
Adjust drum stops for use with desired drums.
4.
Connect outlet fittings and hoses.
5.
Perform test drum unload. See
Start and Adjust the Pump, page 20
System
System
System Setup
Setup
Setup (Electro
(Electro
(Electro---pneumatic
pneumatic
pneumatic
Control)
Control)
Control)
1.
Apply power.
2.
Connect supply air.
3.
Adjust drum stops for use with desired drums.
4.
Set SDU parameters.
See
System Configuration Screen, page 47
5.
Define recipes. See
.
6.
Connect outlet fittings and hoses.
7.
Perform test drum unload.
3A5402J
17