Control
Control
Control Panel
Panel
Panel (Exposed)
(Exposed)
(Exposed)
When supplied with a continuous supply of air, the
control panel can control the SDU functions for
manual unloading of drums.
NOTE:
NOTE:
NOTE: An SDU that uses a static seal will not have
inflatable seal components on the control panel.
AA
Main air slider valve
Turns air on and off to the system. When closed, the valve relieves
pressure downstream.
AB
Ram air regulator
Controls ram up and down pressure and air assist pressure.
AC
Ram air pressure gauge
Displays the air pressure used to raise and lower the ram.
AD
Ram director valve
Controls ram direction.
AE
Air motor regulator
Controls air pressure to the motor.
AF
air motor pressure gauge
Displays the air pressure used to drive the air motor.
AG
Air assist button
Turns air on and off to push the ram plate out of an empty drum.
AH
Air motor slider valve
Turns air on and off to the air motor. When closed, the valve relieves
air trapped between it and the air motor. Push the valve to shutoff.
AJ
Seal air pressure regulator
Controls the air pressure used to inflate the seal.
AK
Seal air pressure gauge
Displays the air pressure used to inflate the seal.
AL
Seal inflate switch
Controls when air is applied to the seal.
AM
Pressure relief valve
Prevents overpressurization of the seal.
10