Branch circuit protection and power disconnect to
be provided by the installer per local code.
AC power is required for an unloader with an
electro-pneumatic control panel.
1.
Route wires to control panel through electrical
conduit. Attach conduit using hole on bottom
right hand side of enclosure with a type 4X rated
conduit hub.
2.
Attach the power system ground wire to the
chassis ground lug (as shown) with 14 AWG
stranded copper wire. Torque to 35 in-lbs (3.95
N
•
m).
3.
Connect equipment to 100 – 240 VAC, single
phase, 50/60 Hz, 15 A service with 14 AWG
stranded copper wire. Attach to L1 and L2 on
power switch as shown. Torque to 8 in-lbs (0.9
N
•
m).
Fluid
Fluid
Fluid Outlet
Outlet
Outlet Line
Line
Line
Connect a grounded, flexible fluid hose (S) to the fluid
outlet port. The port is 2.0 in (50.8 mm) tri-clamp.