Electro-pneumatic Control Panel Display Screens
Automatic
Automatic
Automatic Screen
Screen
Screen
Feedback enabled
Feedback disabled
NOTES:
NOTES:
NOTES:
• To prime a full drum for automatic operation, press
and hold the green start button to advance the
ram plate downwards. Before reaching the top of
the drum, the pump will begin to pump slowly and
the ram plate seal will partially inflate so that an
overfilled drum will not spill over. Continue holding
the start button until the ram plate is below the top
of the drum and the automatic sequence takes
over. If this button is released prior to the automatic
sequence beginning, ram plate movement will
cease. Press and hold the start button to resume.
• When the partial drum setting is selected, pump
operation is delayed until the start button is
released and the ram plate is located below the
rim of the drum. If the ram plate is not below the
rim of the drum when the start button is released,
ram movement ceases.
• If feedback is enabled in system settings:
– The Current Job field is active. The Current Job
box logs how much material has been dispensed
since the previous job was completed.
– The Batching checkbox is active. Selecting the
Batching checkbox enables the Batch Amount
numeric field and enters the value defined in
the selected recipe Default Batch Size field.
When the specified amount has been dispensed,
the evacuation will cease and await further
instruction.
• If Remote Operation is enabled for your SDU, see
.
28