Flushing
26
3A1602H
9.
Purge gun hoses.
a.
Disconnect hoses from gun and secure to a pail
of solvent.
b.
Turn Recirc/Spray valve A to Spray.
c.
Open gun into waste container A.
d.
Set function knob to Slow Recirc
until hose
is flushed.
e.
Set function knob to Stop/Park
.
f.
Repeat for B side.
10. Set function knob to Stop/Park
.
11. Solvent flushing is a two step process. Go back to
step 3, drain solvent, and flush again with fresh sol-
vent.
12. Place fluid inlet tubes in a pail of plasticizer or clean
motor oil and circulate fluid through the system.
Leave fluid in the unit.
NOTE:
Never leave the unit dry unless it has been dis-
assembled and cleaned. If fluid residue dries in the
pumps, the ball checks may stick the next time you use
the unit.
F
IG
. 45
TI17136a
Содержание Reactor E-8p 3A1602H
Страница 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Страница 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Страница 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...