Pressure Relief Procedure
3A1602H
23
Pressure Relief
Procedure
NOTE:
If using the Manual 2K gun,
refer to the Manual
2K gun instruction manual.
1.
Engage piston safety lock.
2.
Set function knob to Stop/Park
.
3.
Turn Recirc/Spray valves to Recirc. Fluid will be
returned to material pails. Pumps will move to the
bottom of their stroke. Ensure gauges drop to 0.
Shutdown
NOTE:
For longer breaks (more than 10 minutes), use
the following procedure. If you will be shut down for
more than three days, perform the
Flushing
procedure,
page 25, first.
NOTE:
If using the Manual 2K gun,
refer to the Manual
2K gun instruction manual.
1.
Follow
Pressure Relief Procedure
.
2.
Close gun fluid valves A and B. Doing this will keep
the internal parts of the gun cleaner and prevent
crossover.
3.
Shut off power.
4.
Loosen rings from pour spouts and remove fluid
inlet tubes from pails. Allow residual fluid to drain
into the appropriate pail.
Trapped air can cause the pump to cycle
unexpectedly, which could result in serious injury
from splashing or moving parts.
F
IG
. 31
F
IG
. 32
F
IG
. 33
+
-
TI17127b
TI17133a
F
IG
. 34
F
IG
. 35
F
IG
. 36
I
O
I
O
O
TI17135a
Ring
TI17125a
Содержание Reactor E-8p 3A1602H
Страница 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Страница 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Страница 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...
Страница 56: ...Dimensions 56 3A1602H Dimensions 34 58 in 87 8 cm 24 12 in 61 3 cm 15 06 in 38 3 cm TI17120a...