Repair
42
3A1602H
Cycle Counter Switch Replacement
F
IG
. 61: Drive Housing
Crankshaft must be in line with crankshaft at other end of motor,
so pumps move up and down in unison.
1
227
220
215
224
210
201
221
214
207
TI17469a
1
MB
216
212
(steel)
213
(bronze)
208
(steel)
211
(bronze)
209
(bronze)
219
213
(bronze)
NOTE:
B side drive housing cover (227) includes the cycle
counter switch (223), mounted in the cover. When reassem-
bling, be sure to install cover with switch on B side.
Feed the cable under the electric motor and through the
grommet and connect to the control board.
TI7028a
223
0.6 in. (15.2 mm)
from inside edge
1.0 in. (25.4 mm) from
inside bottom edge
Содержание Reactor E-8p 3A1602H
Страница 16: ...Setup 16 3A1602H 12 Install fluid tubes 36...
Страница 36: ...Repair 36 3A1602H FIG 56 Function Knob Potentiometer ti17465a 10 61 12 16a 23 22 87 16 N S P...
Страница 40: ...Repair 40 3A1602H FIG 59 Pressure Transducer Connection 35 ti17467a 33...